Figure 32 Selecting a storage system
Figure 33 Checking redundancy
Verifying component failure
Before replacing a disk, use the following methods to verify component failure:
CAUTION:
If HP Command View EVA does not present a status consistent with the disk status indi cators, or if HP
Command View EVA or your system monitoring tool indicates multiple hardware failures, contact HP
support for assistance (h
ttp://www.hp.com/support).
Analyze a ny failure messages received. Error messages identify each disk by its rack, enclosure,
bay, a nd UUID (World Wide Name). Record this information to assist you in identifying the
correct disk before replacing it.
The following is a sample of the disk identication information:
FRU List:
Storage System Name: EVA_1
Storage System World Wide ID: 5000-1FE1-0015-42A0
Disk Drive UUID: 2000-0000-871D-FE60
Drive Location ---
Enclosure ID: 8
Bay ID: 1
Rack Number: 0
NOTE:
The Disk Drive UUID corresponds to the disk No de World Wide Name displayed in HP Command
View EVA.
Check the disk status indicators (Figure 34) . If a hard failure has occurred, the fault indicator
should be On.
Check the disk status using HP Command View EVA:
1. In the Navigation pane, select Storage system > Hardware > Rack > Disk enclosure > Bay.Use
the information from the error message to guide you to the correct disk.
2. In the Content pane, select the Disk Drive tab.
90