Figure 47 Power supply element numbering
The following sections dene the power supply condition reports.
0.2.en.01NONCRITICALConditionPowersupplyACinputmissing
The loss of the AC input to a power supply makes the remaining power supply a single point of failure.
This condition report remains active until AC power is applied to the power supply.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Ensure that there is AC power to the rack PDU, and from the PDU to the PDMs and that the PDU and
PDM circuit breakers are not reset.
If there is no AC power to the PDU, contact building facilities management.
Verify that the power supply AC power cord is properly connected.
3. If AC is present, and the ra ck power distribution circuitry is functioning properly, the power supply
indicator should be on.
4. Observe the EMU to ensure the error is corrected.
5. Contact your authorized service representative.
0.2.en.02
UNRECOVERABLE condition—Power supply missing
This condi
tion re port indicates a power supply is not installed or installed incorrectly. Both of these
conditions affect air ow within the enclosure and can cause an overtemperature condition. Enclosure
shutdown is imminent.
The operat
ional power supply will automatically shut down a fter seven minutes, thereby disabling the
enclosure. This condition report remains active until either the problem is corrected, or the operational
power s upply shuts down, whichever occurs rst.
To correc
t this problem, record all six characters of the condition report, then contact your authorized
service repr esentative.
CAUTION:
Removing power from an enclosure may cause the loss or corruption of data. To avoid this condition, shut
down the s
ystem using H P Command View EVA. An automatic shutdown and possible data corruption
may resul
t if the power supply is removed before a replacement is available.
0.2.en.03CRITICALcondition—Power supply load unbalanced
This condition report indicates that a component within a p ower supply may have failed. This can make
the remaining power supply a single point of failure.
This condition report remains active until corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.