Correcting the error removes the associated condition from the error queue. Replacing the EMU will
also clear the error conditions. The order in which the EMU displays the error queue information is
based on two factors:
The severity of the error
Thetimetheerroroccurred
Themostsevereerrorinthequeuealwayshasprecedence,regardlessofhowlonglesssevereerrorshave
been in the queue. This ensures that the most severe errors are displayed imm ediately.
NOTE:
Whenviewinganerror,theoccurrenceofamoresevereerrortakesprecedenceandthedisplaychanges
to the most sever e error.
The earliest reported condition within an error type has precedence over errors reported later. For
example, if errors at all levels have occurred, the EMU displays them in the following order:
1. UNRECOVERABLE errors in the sequence they occurred.
2. CRITICAL errors in the sequence they o ccurred.
3. NONCRITICAL errors in the sequence they oc curred.
4. INFORMATION conditions in the sequence they occurred.
Error condition report format
Each EMU detected condition generates a condition report containing three pieces of information.
Element type The rst t wo-digit hexadecimal display denes the element type reporting the
problem. The format for this display is e.t. with a period after each character. Valid element
types are 0.1. through F.F.
E lement number The second display is a two-digit decimal number that denes the specicelement
reporting the problem. The format for this display is en. with a period after the second character.
Error code The third display is a two-digit decimal number that denes the specicerrorcode.
The format for this display is ec without any periods.
For detailed information about each condition report, including recommended corrective actions.
Navigating the error condition display
When a n error condition occurs, the alphanumeric display changes to Er and the error menu is active.
Thebuttonsareusedtodisplaytheerrorconditionvalues.
Perform the following procedure to display error conditions. Figure 20 illustrates the sequence for
displaying error conditions.
1. With Er in the display, press and hold the top push button until the rst element type is displayed.
Themostsevereerrorinthequeuewillbedisplayed.
2. Release the top push button when the element type is displayed. The element t ype has both decimal
points lit.
3. Press and release the top push button to display the element number. This display has only the
right decimal point lit.
4. Press and release the top p ush button again to display the error code. This display has no decimal
points lit. Repeated press/release operations will cycle through these three values.
5. Press and hold the top push button from any of the three display states to m ove to the element
type for the next error condition in the queue.
6. Usethetoppushbuttontodisplaythevaluesfortheerrorcondition.
7. When all error conditions have been displayed, press and release the bottom push b ut ton to return
to the Er display.