Hp NetStorage 6000 Bedienungsanleitung Seite 172

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 192
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 171
Troubleshooting and Error Codes
Determining Component Failure
E-7
Temperature out
of range
Check ambient temperature (must be
below 35° C).
Remove airflow restrictions at the front and
back faceplates.
Check fan status reported on front panel
and in NetStorage web interface.
Replace any failed system blowers, or call
an HP service representative if the CPU fan
has failed.
Network Activity Blinking red All network links
are bad or
unattached
Check network cable and connections.
Check hub/switch port function and
protocol settings.
Drive Active (top
row of LEDs on
the front panel)
Off Hard drive not
fully seated
Tighten the screw.
Blinking yellow Drive initializing
or rebuilding
No action required.
Blinking red Drive failure Replace the drive. The drive replacement kit
provides detailed instructions.
LED Light Cause Solution
Seitenansicht 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 191 192

Kommentare zu diesen Handbüchern

Keine Kommentare