Table 35 iSCSI or iSCSI/FCoE module log messages (continued)
Memory unavailable for LUN object.ErrorAppQLBA_CreateLunObject:
LunObject memory unavailable
41067
Unable to create an object for initiator object;
exceeded the maximum number of initiators.
ErrorAppQLBA_CreateInitiatorObject:
Too many initiators
41077
Process control block status indicates that a
peripheral component interface/interconnect (PCI)
error occurred during a target operation.
ErrorAppQLBA_DisplayTargetOperationStatus:
PCI Error, Status 0x%.2x
41096
Process control block status indicates that a direct
memory access (DMA) error occurred during an
initiator operation.
ErrorAppQLBA_DisplayInitiatorOperationStatus:
DMA Error, Status 0x%.2x
41106
Process control block status indicates that a transport
error (protocol) occurred during an initiator
operation.
ErrorAppQLBA_DisplayInitiatorOperationStatus:
Transport Error, Status
0x%.2x
41107
Process control block status indicates that a data
overrun error occurred during an initiator operation.
ErrorAppQLBA_DisplayInitiatorOperationStatus:
Data Overrun, Status 0x%.2x
41111
iSCSI login failed between receipt of protocol data
unit (PDU) and request for the data segment.
ErrorAppQLIS_LoginPduContinue:
Operation failed. Initiator
0x%x, TPB status 0x%x
41234
iSCSI login failed due to unsupported version
number in received login PDU.
ErrorAppQLKV_ValidateLoginTransitCsgNsgVersion
failed (status 0x%x)
41238
iSCSI login PDU contains invalid initiator name. The
format and character set used to form the initiator
name is invalid.
ErrorAppQLIS_LoginPduContinue:
Invalid initiator name.
Initiator:
41257
iSCSI target login was attempted to a portal (iSCSI1
or iSCSI2) on which the target is not presented.
ErrorAppQLIS_LoginPduContinue:
Target not configured for
Portal
41265
iSCSI login PDU received for a target with a target
name unknown to the module.
ErrorAppQLIS_LoginPduContinue:
Target not found. Target
name:
41267
iSCSI login PDU received without a target name for
a normal session.
ErrorAppQLIS_LoginPduContinue:
Missing target name
41268
iSCSI login PDU received without an initiator name
key/value.
ErrorAppQLIS_LoginPduContinue: TSIH
is 0 but InitiatorName
key/value not provided
41270
iSCSI login PDU received with an incorrect initiator
task tag for a session which is partially logged in.
ErrorAppQLIS_LoginPduContinue:
CONN_STATE_IN_LOGIN, Unknown
InitTaskTag
41272
This would occur if a login PDU other than the initial
login PDU used an initiator task tag which was
different than the initiator task tag provided in the
initial login PDU.
iSCSI login PDU was received with a target session
identifying handle (TSIH) out of range. This would
ErrorAppQLIS_LoginPduContinue: TSIH
0x%x out of range
41283
occur if the iSCSI initiator attempting the login failed
to used the TSIH value provided in the Target Login
Response PDU (module is target) in subsequent login
PDUs.
iSCSI login PDU was received with an invalid TSIH
value. The TSIH is invalid because there is no
ErrorAppQLIS_LoginPduContinue:
Session does not exist,
invalid TSIH 0x%x
41284
session with that TSIH value. This would occur if the
iSCSI initiator attempting the login failed to used
the TSIH value provided in the target login response
PDU (module is target) in subsequent login PDUs.
285