Example 1:
MEZ50_02 (admin) #> image cleanup
MEZ50_02 (admin) #> image list
No images found in system.
Example 2:
MEZ50_02 (admin) #> image list
mez50-3_0_4_1.bin
Only the file name is displayed as a response to this command.
The software image file is placed using ftp to the iSCSI or iSCSI/FCoE module as shown in Figure 93
(page 223).
Figure 93 FTP to iSCSI or iSCSI/FCoE module
Example 3:
MEZ50_02 (admin) #> image unpack
Usage: image unpack [ <file> ]
MEZ50_02 (admin) #> image unpack mez50-3_0_4_1.bin
Unpack Completed. A reboot is required for the FW to take affect.
Do you wish to reboot the System at the current time (y/n): y
System will now be rebooted...
MEZ50_02 #>
Initiator
Adds, modifies, and removes an initiator in the module’s database.
Admin sessionAuthority
add
mod
remove
initiatorSyntax
Adds an initiator to the module’s database.addKeywords
Modifies the settings of an initiator.mod
Removes a logged out initiator. You cannot remove an initiator
that is currently logged in.
remove
Example 1:
MEZ50 (admin) #> initiator add
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key
Commands 223
Seitenansicht 222