Table 22 iSCSI or iSCSI/FCoE module secret settings
MS Initiator secret settingsiSCSI or iSCSI/FCoE module secret settings
Setting (example)ActionSetting (example)Source
N/AGeneral Tab SecretN/AiSCSI Port
CHAPsecret01Add Target PortalCHAPsecret01Discovered iSCSI Initiator
CHAPsecret01Log on to TargetN/AiSCSI Presented Target
NOTE: These are examples of secret settings. Configure CHAP with settings that apply to your specific network
environment.
1. Enable CHAP for the iSCSI or iSCSI/FCoE modules discovered iSCSI Initiator entry. CHAP
can be enabled via CLI only. To enable CHAP for the iSCSI or iSCSI/FCoE modules discovered
iSCSI Initiator entry using the iSCSI or iSCSI/FCoE module's CLI:
a. If the iSCSI Initiator is not listed under set chap command:
HP Command View Option: add the initiator iqn name string via HP Command
View’s add host tab.
Go to the HP P6000 Command View and select Hosts then select Add Host tab
and enter the iqn name string.
CLI Option: Enter the initiator add command and add the iSCSI Initiator that is about
to do discovery.
b. If the iSCSI Initiator is listed under set chap command, then enable CHAP secret. For
example: CHAPsecret01:
Select the index of the iSCSI Initiator.
To Enable CHAP, select 0, then type the CHAP secret.
Set up the iSCSI Initiator 133