Appendix B: HP SNMP events 60
Trap types Rules file Description
Netcool
severity
cpqPMTrapCritical (1) 1
This event occurs when a Critical alarm
occurs.
Critical (5)
cpqPMTrapWarning (2) 2
This event occurs when a Warning alarm
occurs.
Minor (3)
cpqPMTrapInformation (3) 3
This event occurs when an information
alarm occurs.
Clear (0)
cpqPMTrapCleared (4) 4
This event occurs when an alarm is
cleared.
Clear (0)
Rack enclosure information (CPQRACK.MIB)
Trap types Rules file Description
Netcool
severity
cpqRackNameChanged (22001) 22001
This event occurs when the rack
name changes.
Clear (0)
cpqRackEnclosureNameChanged
(22002)
22002
This event occurs when the
enclosure name changes.
Clear (0)
cpqRackEnclosureRemoved
(22003)
22003
This event occurs when an
enclosure is removed from the
rack.
Clear (0)
cpqRackEnclosureInserted
(22004)
22004
This event occurs when an
enclosure is inserted into the
rack.
Clear (0)
cpqRackEnclosureTempFailed
(22005)
22005
This event occurs when the
enclosure temperature status is
set to
.
Critical (5)
cpqRackEnclosureTempDegraded
(22006)
22006
This event occurs when the
enclosure temperature status set
to
.
Major (4)
cpqRackEnclosureTempOk
(22007)
22007
This event occurs when the
enclosure temperature status is
set to
.
Clear (0)
cpqRackEnclosureFanFailed
(22008)
22008
This event occurs when the
enclosure fan status is set to
.
Critical (5)
cpqRackEnclosureFanDegraded
(22009)
22009
This event occurs when the
enclosure fan status is set to
.
Major (4)
cpqRackEnclosureFanOk (22010) 22010
This event occurs when the
enclosure fan status is set to
.
Clear (0)
cpqRackEnclosureFanRemoved
(22011)
22011
This event occurs when the
enclosure fan is removed.
Minor (3)
cpqRackEnclosureFanInserted
(22012)
22012
This event occurs when the
enclosure fan is installed.
Clear (0)