Appendix C: Non-HP SNMP events 175
Appendix C: Non-HP SNMP events
Non-HP SNMP events
The following table lists all of the non-HP SNMP definitions delivered with rules file for
Netcool/OMNIbus version 5.0. The events are organized according to MIB type and object
identifier.
Fibre Channel Management (FCMGMT-MIB)
Trap types Rules file Description
Netcool
severity
connUnitStatusChange (1)
This event occurs when overall
status of the connectivity unit
changes.
connUnitStatus:unused connUnitStatus.2 Minor (3)
ConnUnitStatus:ok connUnitStatus.3 Clear (0)
connUnitStatus:Warning connUnitStatus.4 Minor (3)
connUnitStatus:failed connUnitStatus.5 Major (4)
connUnitDeletedTrap (3) 3
This event occurs when the
connectivity unit is deleted from the
agent.
Minor (3)
connUnitEventTrap (4) 4
This event occurs when an event is
generated by the connectivity unit.
Clear (0)
connUnitSensorStatusChange (5)
This event occurs when overall
status of sensor of the connectivity
unit changes.
connUnitSensorStatus:other
connUnitSensorStat
us.2
Minor (3)
connUnitSensorStatus:ok
connUnitSensorStat
us.3
Clear (0)
connUnitSensorStatus:Warning
connUnitSensorStat
us.4
Minor (3)
connUnitSensorStatus:failure
connUnitSensorStat
us.5
Major (4)
connUnitPortStatusChange (6)
This event occurs when overall
status of port of the connectivity
unit changes.
connUnitPortStatus:unused
connUnitPortStatus
.2
Minor (3)
connUnitPortStatus:ready
connUnitPortStatus.
3
Clear (0)
Seitenansicht 174