Appendix B: HP SNMP events 49
Trap types Rules file Description
Netcool
severity
CpqFcTapeCntlrStatus:offline
CpqFcTapeCntlrStatu
s.3
— Major (4)
cpqFcaCntlrActive (16014) 16014
This event occurs when the
backup array controller in a
duplexed pair switches to the
active role.
Clear (0)
cpqFca2PhyDrvStatusChange
(16016)
—
This event occurs when the status
of a physical drive changes.
—
CpqFcaPhyDrvStatus:unconfigure
d
1cpqHeCorrMemLog
Status.2
— Minor (3)
CpqFcaPhyDrvStatus:ok
1cpqHeCorrMemLog
Status.3
— Clear (0)
CpqFcaPhyDrvStatus:threshExce
eded
1cpqHeCorrMemLog
Status.4
— Major (4)
CpqFcaPhyDrvStatus:predictiveF
ailure
1cpqHeCorrMemLog
Status.5
— Major (4)
CpqFcaPhyDrvStatus:failed
1cpqHeCorrMemLog
Status.6
— Critical (5)
CpqFcaPhyDrvStatus:unsupporte
d
1cpqHeCorrMemLog
Status.7
— Major (4)
cpqFca2AccelStatusChange
(16017)
—
This event occurs when the status
of an array accelerator cache
board changes.
—
CpqFcaAccelStatus:invalid CpqFcaAccelStatus.2 — Minor (3)
CpqFcaAccelStatus:enable CpqFcaAccelStatus.3 — Clear (0)
CpqFcaAccelStatus:tmpDisabled CpqFcaAccelStatus.4 — Minor (3)
CpqFcaAccelStatus:permDisable
d
CpqFcaAccelStatus.5 — Major (4)
cpqFca2AccelBadDataTrap
(16018)
16018
This event occurs when an array
accelerator cache board loses
battery power.
Major (4)
cpqFca2AccelBatteryFailed
(16019)
16019
This event occurs when a battery
associated with the array
accelerator cache board fails.
Major (4)
cpqFca2CntlrStatusChange
(16020)
—
This event occurs when the status
of an external array controller
changes.
—
CpqFcaCntlrStatus:ok CpqFcaCntlrStatus.2 — Clear (0)
CpqFcaCntlrStatus:failed CpqFcaCntlrStatus.3 — Critical (5)
CpqFcaCntlrStatus:offline CpqFcaCntlrStatus.4 — Major (4)
CpqFcaCntlrStatus:redundantPat
hOffline
CpqFcaCntlrStatus.5 — Minor (3)
CpqFcaCntlrStatus:notConnected CpqFcaCntlrStatus.6 — Minor (3)