129
.MAXRETRY
This event is generated by PHONHOME, PHSYSOP, or PAGE. It will
occur after the value entered for the Max. Retries system parameter is
surpassed.
Example:
Alarm/Event Action Routine Parameters Comments
.MAXRETRY PHONHOME 2
This example initiates a PHONHOME to Home Phone Number 2, as
defined in the System Parameter table, when the maximum retry
counter has been exceeded.
.MDMINITERR
This alarm is generated when a modem initialization error occurs.
Alarm/Event Action Routine Parameters Comments
.MDMINITERR SNMPTRAP 1 Modem error
.MEMLOW
The alarm .MEMLOW is generated on the hour if fewer than 4KB (4096
bytes) are available on the Terminal server variable area.
Example:
Alarm/Event Action Routine Parameters Comments
.MEMLOW PHONHOME Memory low