HP ProLiant Generation ML310 Spezifikationen Seite 1

Stöbern Sie online oder laden Sie Spezifikationen nach Server HP ProLiant Generation ML310 herunter. HP ProLiant Generation ML310 Specifications Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 80
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HP ProLiant ML310 Generation 5 Server
Maintenance and Service Guide
Part Number 450223-004
August 2008 (Fourth Edition)
Seitenansicht 0
1 2 3 4 5 6 ... 79 80

Inhaltsverzeichnis

Seite 1 - August 2008 (Fourth Edition)

HP ProLiant ML310 Generation 5 Server Maintenance and Service Guide Part Number 450223-004 August 2008 (Fourth Edition)

Seite 2 - Intended audience

Customer self repair 10 periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie word

Seite 3 - Contents

Customer self repair 11 Serviço de garantia apenas para peças A garantia limitada da HP pode incluir um serviço de garantia apenas para peças. Segun

Seite 4 - Contents 4

Customer self repair 12

Seite 5 - Customer self repair

Customer self repair 13

Seite 6 - Customer self repair 6

Customer self repair 14

Seite 7 - Customer Self Repair

Customer self repair 15

Seite 8 - Customer self repair 8

Illustrated parts catalog 16 Illustrated parts catalog Mechanical components Item Description Spare part number Customer self repair (on pa

Seite 9

Illustrated parts catalog 17 3No—Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires tha

Seite 10 - Reparo feito pelo cliente

Illustrated parts catalog 18 2Optional: Opcional—Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo fe

Seite 11 - Customer self repair 11

Illustrated parts catalog 19 System components Item Description Spare part number Customer self repair (on page 5) System components 5 F

Seite 12 - Customer self repair 12

© Copyright 2007, 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warra

Seite 13 - Customer self repair 13

Illustrated parts catalog 20 Item Description Spare part number Customer self repair (on page 5) h) 2.40-GHz Intel® Xeon® 3220, quad-core, 8-MB

Seite 14 - Customer self repair 14

Illustrated parts catalog 21 Item Description Spare part number Customer self repair (on page 5) 12 DV D-ROM drive 447464-001 Mandatory1 Power

Seite 15 - Customer self repair 15

Illustrated parts catalog 22 3No: Non—Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour

Seite 16 - Illustrated parts catalog

Illustrated parts catalog 23

Seite 17

Removal and replacement procedures 24 Removal and replacement procedures Required tools You need the following items for some procedures: • T-10/T-

Seite 18

Removal and replacement procedures 25 WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system c

Seite 19 - System components

Removal and replacement procedures 26 WARNING: This server is very heavy. To reduce the risk of personal injury or damage to the equipment: • Obs

Seite 20

Removal and replacement procedures 27 Unlock the bezel Unlock and remove the bezel before accessing the hard drive cage and media bays. Unlock the b

Seite 21

Removal and replacement procedures 28 3. Remove the bezel. To replace the component, reverse the removal procedure. Access panel WARNING: To

Seite 22

Removal and replacement procedures 29 3. Remove a bezel blank. To replace the component, reverse the removal procedure. Media bay blank To remove

Seite 23

Contents 3 Contents Customer self repair ...

Seite 24 - Safety considerations

Removal and replacement procedures 30 Hard drive blank Remove the component as indicated. To replace the component, slide the component into the ba

Seite 25 - Rack warnings

Removal and replacement procedures 31 3. Remove the hard drive. To replace the component: 1. Slide the drive into the cage until it clicks, locki

Seite 26 - Preparation procedures

Removal and replacement procedures 32 6. Remove the power button/LED cable. To replace the component, reverse the removal procedure. Temperature

Seite 27 - Unlock the bezel

Removal and replacement procedures 33 Front USB connectors To remove the component: 1. Power down the server (on page 26). 2. Remove the bezel (&q

Seite 28 - Bezel blank

Removal and replacement procedures 34 Diskette drive CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless a

Seite 29 - Media bay blank

Removal and replacement procedures 35 5. Remove the SATA optical drive. To replace the component, reverse the removal procedure. Full-height tape

Seite 30 - Hard drives

Removal and replacement procedures 36 5. Remove the full-height tape drive. To replace the component, reverse the removal procedure. USB tape dri

Seite 31 - Power button/LED cable

Removal and replacement procedures 37 5. Remove the USB tape drive. To replace the component, reverse the removal procedure. Hard drive cage and

Seite 32 - Temperature sensor

Removal and replacement procedures 38 To replace the component, reverse the removal procedure. Rear fan and fan holder To remove the component: 1.

Seite 33 - USB diskette drive

Removal and replacement procedures 39 System air baffle and PCI card guide To remove the component: WARNING: To reduce the risk of personal inju

Seite 34 - SATA optical drive

Contents 4 Cabling ...

Seite 35 - Full-height tape drive

Removal and replacement procedures 40 6. Remove the PCI fan. To replace the component, reverse the removal procedure. Non-redundant power supply

Seite 36 - USB tape drive

Removal and replacement procedures 41 Hot-plug power supply CAUTION: Leave all failed power supplies installed until ready to replace with a wor

Seite 37

Removal and replacement procedures 42 6. Remove the redundant power supply backplane assembly. To replace the component, reverse the removal proce

Seite 38 - Rear fan and fan holder

Removal and replacement procedures 43 You can expand server memory by installing PC2-6400 DDR2 SDRAM DIMMs. The system supports up to four DIMMs for

Seite 39 - PCI fan

Removal and replacement procedures 44 To replace the heatsink: 1. Use the alcohol swab to remove all the existing thermal grease from the proces

Seite 40 - Non-redundant power supply

Removal and replacement procedures 45 3. Align and install the heatsink with the arrow on the heatsink label pointing to the front of the server.

Seite 41 - Hot-plug power supply

Removal and replacement procedures 46 5. Open the processor retaining latch and the processor socket retaining bracket. 6. Using your fingers, re

Seite 42

Removal and replacement procedures 47 1. If the processor has separated from the installation tool, carefully re-insert the processor in the tool.

Seite 43 - Heatsink

Removal and replacement procedures 48 3. Press down firmly until the processor installation tool clicks and separates from the processor, and then

Seite 44

Removal and replacement procedures 49 6. Apply all the grease to the top of the processor in one of the following patterns to ensure even distribut

Seite 45 - Processor

Customer self repair 5 Customer self repair HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow fo

Seite 46

Removal and replacement procedures 50 Expansion boards To remove the component: 1. Power down the server (on page 26). 2. Unlock the bezel (on pag

Seite 47

Removal and replacement procedures 51 6. Remove the PCI-X extender board. To replace the component, reverse the removal procedure. Battery If the

Seite 48

Removal and replacement procedures 52 4. Remove the battery. To replace the component, reverse the removal procedure. IMPORTANT: After replaci

Seite 49

Removal and replacement procedures 53 10. Open the processor retaining latch and the processor socket retaining bracket. CAUTION: To avoid

Seite 50 - PCI-X extender board

Removal and replacement procedures 54 11. Using your fingers, remove the processor from the failed system board. CAUTION: To avoid damage to t

Seite 51 - Battery

Removal and replacement procedures 55 a. Open the processor retaining latch and the processor socket retaining bracket. b. Remove the processor s

Seite 52 - System board

Removal and replacement procedures 56 5. Close the processor retaining latch and the processor socket retaining bracket. 6. Clean the old ther

Seite 53

Removal and replacement procedures 57 7. Apply all the grease to the top of the processor in one of the following patterns to ensure even distribut

Seite 54

Removal and replacement procedures 58 10. Install all components removed from the failed system board. 11. Install the access panel. 12. Lock the

Seite 55

Cabling 59 Cabling Server cabling Item Description 1 SATA hard drive cable (hard drive) 2 Front USB cable 3 SATA optical drive cable 4 Front

Seite 56

Customer self repair 6 • Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à HP de remplacer ces p

Seite 57

Cabling 60 SATA hard drive cabling Item Description 1 Power cable 2 SATA cable SAS hard drive cabling Item Description 1 Power cable 2 SAS

Seite 58 - Server feet

Diagnostic tools 61 Diagnostic tools Troubleshooting resources The HP ProLiant Servers Troubleshooting Guide provides procedures for resolving commo

Seite 59 - Cabling

Diagnostic tools 62 Survey functionality is installed with every SmartStart-assisted HP Insight Diagnostics installation, or it can be installed thr

Seite 60 - SAS hard drive cabling

Component identification 63 Component identification Front panel components Item Description 1 DVD-ROM drive 2 Media bays (bezel blanks) 3 USB

Seite 61 - Diagnostic tools

Component identification 64 Front panel LEDs and buttons Item Description Status 1 DVD-ROM drive ejector button — 2 DVD-ROM drive activity L

Seite 62 - ROMPaq disaster recovery

Component identification 65 SAS and SATA device numbers Hot-plug SATA or SAS hard drive LEDs Item LED description Status 1 Fault/UID status

Seite 63 - Component identification

Component identification 66 The online/activity status LED will not illuminate if using SATA drives connected to the embedded storage device. In thi

Seite 64 - Front panel LEDs and buttons

Component identification 67 Rear panel LEDs • Redundant hot-plug power supply model Item LED Status 1 NIC/iLO 2 link On = Link Off = No lin

Seite 65 - SAS and SATA device numbers

Component identification 68 Item LED Status 1 NIC/iLO 2 link On = Link Off = No link 2 NIC/iLO 2 activity Flashing = Activity Off = No activ

Seite 66 - Rear panel components

Component identification 69 Item Description 17 System maintenance switch 18 PCI fan connector 19 System battery 20 SATA connector 4 (hard drive)

Seite 67 - Rear panel LEDs

Customer self repair 7 NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richi

Seite 68 - System board components

Component identification 70 Position Default Function S7 Off Reserved S8 Off Reserved When the system maintenance switch position 6 is set to th

Seite 69 - System maintenance switch

Component identification 71 System board LEDs Item LED description Status 1 Processor failure Amber = A multibit error has occurred. Off = No

Seite 70 - NMI functionality

Component identification 72 System LEDs and internal health LED combinations When the internal health LED on the front panel illuminates either ambe

Seite 71 - System board LEDs

Component identification 73 PCI-X extender board components Item Description 1 PCI-X expansion slot 1 2 System board connector Fan location

Seite 72

Specifications 74 Specifications Environmental specifications Specification Value Temperature range* Operating 10 °C to 35°C (50°F to 95°F) Shi

Seite 73 - Fan locations

Specifications 75 Specification Value Maximum peak power 410 W (non-redundant non-hot-plug) 430 W (redundant hot-plug) * 100 to 127 VAC is required

Seite 74 - Specifications

Acronyms and abbreviations 76 Acronyms and abbreviations CMOS complementary metal-oxide semiconductor CSR Customer Self Repair DDR2 double data ra

Seite 75 - Specification Value

Acronyms and abbreviations 77 SAS serial attached SCSI SATA serial ATA SCSI small computer system interface UID unit identification UPS uninterr

Seite 76 - Acronyms and abbreviations

Index 78 A access panel 16, 28 additional information 61 air baffle 39 B battery 51, 70 bezel 16, 27 bezel blank 28 bezel key 19 bezel

Seite 77

Index 79 I iLO (Integrated Lights-Out) 69 IML (Integrated Management Log) 62 Insight Diagnostics 61 Integrated Management Log (IML) 62 intern

Seite 78 - Index 78

Customer self repair 8 anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-Ersatzteil geliefert wer

Seite 79 - Index 79

Index 80 SATA optical drive 34 serial connector 66, 68 serial number 52 server feet 16, 58 server specifications 74 server, front panel LED

Seite 80 - Index 80

Customer self repair 9 Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la su

Kommentare zu diesen Handbüchern