HP 16 processor Hauptspezifikationen

Stöbern Sie online oder laden Sie Hauptspezifikationen nach Server HP 16 processor herunter. HP 16 processor QuickSpecs Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 60
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
As the leading 2P 2U AMD rack server, the HP ProLiant DL385 G7 is designed with virtualization in mind, yet flexible and
expandable to support any business need in many environments from corporate datacenters to sophisticated SMBs.
Front View:
Front View:Front View:
Front View:
Rear View:
Rear View:Rear View:
Rear View:
1.
Redundant Power Supplies
1.
PCI slot 5
2.
Two HP NC382i Dual Port Multifunction NICs
2.
PCI slot 6
3.
SD Card Reader
3.
PCI slot 4
4.
PCI Riser Slots
4.
PCI slot 2
5.
Quick Removal Access Panel
5.
PCI slot 3
6.
AMD Opteron Processors (up to 2)
6.
PCI slot 1
7.
Hot Plug Redundant Fans
7.
Power Supply 2
8.
Hard Drive Bays
8.
Power Supply 1
9.
Slimline Optical bay
9.
USB Connectors (2)
10.
UID LED Button
10.
Video Connector
11.
Health LED
11.
NIC 1 Connector
12.
Power On/Standby Button and System Power LED
12.
NIC 2 Connector
13.
USB Connectors (2)
13.
Mouse Connector
14.
Video Connector
14.
Keyboard Connector
15.
System Insight Display
15.
Serial Connector
16.
Twenty-four sockets for DDR3 Memory
16.
iLO3 connector
17.
NIC 3 Connector
18.
NIC 4 Connector
What's New
What's NewWhat's New
What's New
Support for 4-core AMD Opteron™ 6204 processor
Support for 1600MHz DDR3 memory kits
QuickSpecs
HP ProLiant DL385 Generation 7 (G7)
HP ProLiant DL385 Generation 7 (G7)HP ProLiant DL385 Generation 7 (G7)
HP ProLiant DL385 Generation 7 (G7)
Overview
DA - 13594 Worldwide — Version 36 — February 13, 2012
Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 59 60

Inhaltsverzeichnis

Seite 1 - QuickSpecs

As the leading 2P 2U AMD rack server, the HP ProLiant DL385 G7 is designed with virtualization in mind, yet flexible andexpandable to support any bus

Seite 2

HP Insight managementHP Insight managementHP Insight managementHP Insight managementsoftwaresoftwaresoftwaresoftwareHP Insight ControlHP Insight Contr

Seite 3

High PerformanceHigh PerformanceHigh PerformanceHigh PerformanceClustersClustersClustersClustersHP Cluster PlatformsHP Cluster Platforms are specifica

Seite 4

Service and SupportService and SupportService and SupportService and SupportHP Technology Services for Industry Standard Servers and BladeSystemHP Tec

Seite 5

Standard CareStandard CareStandard CareStandard CareStandard Care Package: Package that maintains high level of server availabilityStandard Care Packa

Seite 6

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Seite 7

WarrantyWarrantyWarrantyWarrantyServer Warranty includes 3-Year Parts, 3-Year Labor, 3-Year Onsite supportwith next business day response.HP ProLiant

Seite 8

Storage ControllerStorage ControllerStorage ControllerStorage ControllerHP Smart Array P410i/512MB FBWC ControllerHard DriveHard DriveHard DriveHard D

Seite 9

6136 1P 8GB-R6136 1P 8GB-R6136 1P 8GB-R6136 1P 8GB-RP410i/256 Hot Plug 1P410i/256 Hot Plug 1P410i/256 Hot Plug 1P410i/256 Hot Plug 1SFF 460W PS Base S

Seite 10

High Efficiency ModelsHigh Efficiency ModelsHigh Efficiency ModelsHigh Efficiency ModelsHP ProLiant DL385 G7HP ProLiant DL385 G7HP ProLiant DL385 G7HP

Seite 11

NOTE:NOTE:NOTE:NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations areord

Seite 12

NOTE:NOTE:NOTE:NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information -

Seite 13

HP DL385 G7 AMD Opteron™ 6238 (2.60GHz/12-core/16MB/115W) FIOProcessor Kit654872-L21HP DL385 G7 AMD Opteron™ 6234 (2.40GHz/12-core/16MB/115W) FIOProce

Seite 14

HP 4GB (1x4GB) Single Rank x4 PC3L-10600 (DDR3-1333) Registered CAS-9 LowPower Memory Kit604500-B21HP 8GB (1x8GB) Single Rank x4 PC3-12800 (DDR3-1600)

Seite 15

Step 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integratable OptionsStep 3: Choose Additional Factory Integrat

Seite 16

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Seite 17

HP DL385 G7 AMD Opteron™ 6128HE (2.0GHz/8-core/12MB/85W) Processor Kit585332-B21Quad-Core ProcessorsQuad-Core ProcessorsQuad-Core ProcessorsQuad-Core

Seite 18

HP Optical DrivesHP Optical DrivesHP Optical DrivesHP Optical DrivesHP Slim 12.7mm SATA DVD-ROM Optical Drive481041-B21HP Slim 12.7mm SATA DVD-RW Opti

Seite 19

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18000.www1.hp.com/products/quickspecs/12

Seite 20

HP 400GB 6G SAS MLC SFF (2.5-inch) Enterprise Mainstream 3yr Warranty SolidState Drive632504-B21HP 200GB 6G SAS MLC SFF (2.5-inch) Enterprise Mainstre

Seite 21

HP I/O ExpansionHP I/O ExpansionHP I/O ExpansionHP I/O ExpansionOptionsOptionsOptionsOptionsHP DL38X G5p/G6/G7 PCI-E x16 Riser Kit494323-B21HP DL38X (

Seite 22

NOTE:NOTE:NOTE:NOTE: Some options may not be integrated at the factory. To ensure only valid configurations are ordered, HP recommends the useof an HP

Seite 23

UpgradeabilityUpgradeabilityUpgradeabilityUpgradeabilityUpgradeable to two processorsMemory ProtectionMemory ProtectionMemory ProtectionMemory Protect

Seite 24

HP Insight Management Media KitNOTE:NOTE:NOTE:NOTE: Insight Software DVD media without licenses. Contains HP Systems InsightManager, HP Insight Contro

Seite 25

HP I/O AcceleratorHP I/O AcceleratorHP I/O AcceleratorHP I/O AcceleratorOptionsOptionsOptionsOptionsHP 160GB Single Level Cell PCIe ioDrive for ProLia

Seite 26

HP 256MB P-series Cache UpgradeNOTE:NOTE:NOTE:NOTE: Supported on HP Smart Array P212 Controller and HP Smart ArrayP410/Zero Memory Controller only.462

Seite 27

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for Technical Specifications and additionalinformation:http://h18004.www1.hp.com/products/quickspecs/13

Seite 28

HP MSL4048 2 LTO-5 Ultrium 3000 SAS Tape LibraryNOTE:NOTE:NOTE:NOTE: Connection using HP Smart Array P212/Zero Memory Controller (462828-B21) recommen

Seite 29

HP Storage OptionsHP Storage OptionsHP Storage OptionsHP Storage OptionsFibre Channel HBAFibre Channel HBAFibre Channel HBAFibre Channel HBANOTE:NOTE:

Seite 30

HP Modular Smart ArrayHP Modular Smart ArrayHP Modular Smart ArrayHP Modular Smart ArrayMSA SAN Storage ArraysMSA SAN Storage ArraysMSA SAN Storage Ar

Seite 31

NOTE:NOTE:NOTE:NOTE: Please see the QuickSpecs for additional information:http://h18000.www1.hp.com/products/quickspecs/14110_div/14110_div.html(World

Seite 32

HP Intelligent PowerHP Intelligent PowerHP Intelligent PowerHP Intelligent PowerDistribution UnitsDistribution UnitsDistribution UnitsDistribution Uni

Seite 33

NOTE:NOTE:NOTE:NOTE: Quick deploy rail system provides tool-free support for racks with square orround mounting holes (including Compaq/HP 7000, 9000,

Seite 34

NOTE:NOTE:NOTE:NOTE: Bus number - Default bus assignment (in decimal). Inserting cards with PCI bridges may alter theactual bus assignment numberNOTE:

Seite 35

HP USB and SD OptionsHP USB and SD OptionsHP USB and SD OptionsHP USB and SD OptionsHP USB 04 Standard KeyboardDT528A#ABAHP 4GB Secure Digital High Ca

Seite 36

NOTE:NOTE:NOTE:NOTE: Memory configurations listed do not apply to "Factory Integrated Models".Memory configurationsMemory configurationsMemo

Seite 37

Processor memory socketProcessor memory socketProcessor memory socketProcessor memory socket7777 8888 999910101010 11111111 12121212Rank support per m

Seite 38

Memory modulesMemory modulesMemory modulesMemory modulesPer channelPer channelPer channelPer channelQRQRQRQRSR or DRSR or DRSR or DRSR or DRMemory mod

Seite 39

Processor memory socketProcessor memory socketProcessor memory socketProcessor memory socket7777 8888 999910101010 11111111 12121212Standard Memory2G

Seite 40

Following are memory options available from HP: HP MemoryHP MemoryHP MemoryHP MemoryNOTE:NOTE:NOTE:NOTE: DIMM banks are active only when the correspon

Seite 41

1-8Eight SFF SAS hot plug hard drive bays 1-16Sixteen SFF SAS hot plug hard drive baysNOTE:NOTE:NOTE:NOTE: This configuration does not support opt

Seite 42

300GB 6G SAS 15K300GB 6G SAS 10K146GB 6G SAS 15K72GB 6G SAS 15KDepending onModelHP Smart Array P410/512 MB BBWC ControllerHP Smart Array P411/256 MB C

Seite 43

HP Smart Array P411/512 MB BBWC ControllerHP Smart Array P812/512 BBWC ControllerSATA Hot Plug LFF (3.5-inch) Midline (MDL) DrivesSATA Hot Plug LFF (3

Seite 44

6G SAS Hot Plug Enterprise Performance Solid State Drives6G SAS Hot Plug Enterprise Performance Solid State Drives6G SAS Hot Plug Enterprise Performan

Seite 45

(2) x8 PCI-E Riser(2) x8 PCI-E Riser(2) x8 PCI-E Riser(2) x8 PCI-E Riser(Optional Primary)ExpansionExpansionExpansionExpansionSlots #Slots #Slots #Slo

Seite 46

Maximum Storage CapacityMaximum Storage CapacityMaximum Storage CapacityMaximum Storage Capacity - (with MSA70)Internal16TB (16 x 1TB SAS SFF)External

Seite 47

HP SCSI TapeHP SCSI TapeHP SCSI TapeHP SCSI TapeAutoloadersAutoloadersAutoloadersAutoloadersDAT 72x10 Autoloader1/8 G2 AutoloaderExternalHP SC11Xe Ult

Seite 48

HP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply KitHP 460W Common Slot Gold Hot Plug Power Supply Kit

Seite 49

HP 750W Common Slot Gold Hot Plug Power Supply KitHP 750W Common Slot Gold Hot Plug Power Supply KitHP 750W Common Slot Gold Hot Plug Power Supply Kit

Seite 50

HP 1200W Common Slot Platinum Hot Plug Power Supply KitHP 1200W Common Slot Platinum Hot Plug Power Supply KitHP 1200W Common Slot Platinum Hot Plug P

Seite 51

System UnitSystem UnitSystem UnitSystem UnitDimensionsDimensionsDimensionsDimensions (H x W x D)(with bezel)3.38 x 17.54 x 27.25 in (8.59 x 44.54 x 69

Seite 52

750 W (at 100 to 120 VAC),750 W (at 200 to 240 VAC)For 460 W Power Supply:460 W (at 100 to 120 VAC),460 W (at 200 to 240 VAC)Maximum Peak Power For 12

Seite 53

Operating 1P SKU 2P SKU LWAd5.3 B 5.6 B LpAm36 dBA 38 dBAEmissions ClassificationEmissions ClassificationEmissions ClassificationEmissions Classificat

Seite 54

Client Browser SupportClient Browser SupportClient Browser SupportClient Browser SupportMicrosoft Internet Explorer 8Microsoft Internet Explorer 7Micr

Seite 55

RAID 1+0 (Striping & Mirroring)RAID 0 (Striping), RAID 1 (Mirroring)Two HP NC382i DualTwo HP NC382i DualTwo HP NC382i DualTwo HP NC382i DualPort M

Seite 56

Maximum InternalMaximum InternalMaximum InternalMaximum InternalStorageStorageStorageStorageHot Plug SFF SAS16TB16 x 1TB (with optional SFF drive cage

Seite 57

© Copyright 2012 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice.Microsoft and Windows N

Seite 58

HP's ProLiant Common Slot Power supplies (1200W, 750W & 460W) meet multiple Energy EfficiencyInitiatives including Climate Savers Computing I

Seite 59

these products. It offers combined firmware and systems software packagingand improved processes for drivers, utilities, agents, non agents, and other

Seite 60

Intelligent ManageabilityIntelligent ManageabilityIntelligent ManageabilityIntelligent ManageabilityHP Systems Insight Manager softwareSmartStartManag

Kommentare zu diesen Handbüchern

Keine Kommentare