No changes to the hub’s default configuration are required for the hub to operate correctly.
The hubs each have a console interface for customizing the hub’s configuration, monitoring
its activity, and running diagnostics.
To configure the hub, first connect a terminal or PC running a terminal emulator, as
described under “Console Connection” below. Then, use the console interface to change
the desired hub configuration parameters. The commands that you can use to change the
hub’s configuration are listed and described later in this section under “Configuration
Commands”.
(The HP 28688B Hub Plus and HP 28699A Hub Plus/48 can also be configured over the
network from an HP network management station. See the network management product
documentation for more information.)
Console Connection
Connect a terminal to the hub’s console port directly or through modems, as described
below.
Connecting a Terminal Directly
1. Connect a terminal, or a PC emulating a terminal, to the console port using an
RS-232-C cable. (For pin-outs and recommended cables see appendix A, “Cables
and Connectors”.)
2. Switch on the terminal’s power (or switch on the PC’s power and start the
terminal emulation program). Configure the terminal for 8 bits per character, 1
stop bit, no parity, Xon/Xoff handshaking, and a baud rate of 9600, 2400, 1200, or
300.
3. Press RETURN several times for the prompt, =>. The baud rate for
communication between the hub and the terminal is set automatically when you
press RETURN.
4. Customize the hub’s configuration (if needed)