Using LO100 44
o On ProLiant ML110 G4 servers, verify or change the following settings:
Configure Console Redirection
— Console Redirection—Enabled
— EMC Support (SPCR)—Enabled
— Flow Control—None
— Redirection After BIOS POST—Always
— Terminal Type—VT100
— Sredir Memory Display Delay—No Delay
I/O Device Configuration—Configure IO Port
— Serial Port 1 Address—3F8/IRQ4
o On ProLiant ML115 G1 servers, verify or change the following settings:
Configure Console Redirection
— Console Redirection—Enabled
— EMS Support (SPCR)—Enabled
— Flow Control—None
— Redirection After BIOS POST—Always
— Terminal Type—VT100
— Sredir Memory Display Delay—No Delay
I/O Device Configuration-Configure IO Port
— Serial Port 1 Address—3F8/IRQ4
o On ProLiant DL140 G3 and ProLiant DL145 G3 servers, verify or change the following settings:
Console Redirection
— Console Redirection—Enabled
— EMS Console—Enabled
— Baud Rate—115.2K
— Console Type—VT100+
— Flow Control—None
— Continue C.R. after POST—Enabled
I/O Device
— Serial Port Mode—BMC
— Serial Port A—Enabled
— Base I/O address—3F8
— Interrupt—IRQ 4
o On ProLiant ML150 G3 servers, verify or change the following settings:
Console Redirection
— BIOS Serial console—Enabled
— EMC Support (SPCR)—Enabled