Hp NonStop G-Series Bedienungsanleitung Seite 79

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 181
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 78
5157/5157 ACL S-Series DLT Subsystems installation Users Guide
Installing and Configuring the 5157 ACL Tape Subsystem
5-6
5. Note that the Library SCSI ID is set to 3. If the DLT1 bus ID needs to
be set to 5, make sure the ÷ is next to line 1, and press the ü button
repeatedly until the display scrolls as shown in Figure 5-7.
Library Bus ID: é
*3
÷÷DLT1 Bus ID:
*5
Figure 5-7 Set SCSI Submenu Scrolled
NOTE: If the drive is being daisy chained, the drive ID must be changed
to ID 4. The library needs to be set to ID 2 to avoid SCSI conflicts.
6. With the ÷ next to line 3, press the Enter button. The ÷ moves to line
4, the é appears at the end of line 1, and the ê appears at the end of
line 4. Use the ù and ü buttons to scroll line 4 to display the possible
settings. Scroll so that 5 is displayed, then press the Enter button to
save the new selection. An * appears at the left of the 5 to indicate that
it is the current selection.
7. Press the Escape button repeatedly until the submenu in Figure 5-5
re-appears.
8. Repeat this procedure for each configuration option that needs to be
change.
Seitenansicht 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 ... 180 181

Kommentare zu diesen Handbüchern

Keine Kommentare