Chapter Five - SCSI Bridge Electronics
Note: Because the beginning of tape is written to every time a tape is unloaded, this area of
the tape tends to wear sooner than the rest of the tape media's length. As a result, it is not
unusual to experience rewrites or ECCs at the beginning of tape. If these situations occur, the
predetermined thresholds can be exceeded early, but the percentage then drops below the
threshold as reading or writing moves further down the tape. To signal this, the error-alert LED
blinks when the error rates currently exceed the set values. It returns to a steady illumination
if, once exceeded, the error rate falls below the set value.
Rwr% 0.5
Ecc:80.5
PRESS to
Alter
Rwr% 0.5
Ecc:80.5
PRESS to
Incremnt
Rwr% 0.5
Ecc:80.5
PRESS to
Incremnt
Rwr%30.5
Ecc:80.5
PRESS to
Incremnt
Rwr%30.7
Ecc:80.5
PRESS to
Alter
Rwr%30.7
Ecc:20.5
PRESS to
Incremnt
Rwr%30.7
Ecc:24.5
PRESS to
Incremnt
Rwr%30.7
Ecc:24.2
PRESS to
Incremnt
Rwr%30.7
Ecc:24.2
PRESS if
Done
Figure 33 Setting error-alert (ECC/Rewrite percentages) thresholds
5.12 Setup 2 Configuration Display Format Items
Enter
Set-Up 2
PRESS to
Select
K
ey
:2.01
[
288FEA
]
*NOT sel
ectable*
O
ptions:
00001401
PRESS to
Alter
BaudRate
9600
bps
PRESS to
Alter
EM: ----
NONE
*NOT sel
ectable*
Exit
Set-Up 2
PRESS to
Select
Figure 34 Setup 2 configuration items
5.12.1 Editing option access key
This is factory-configured and is not selectable.
K
ey
:7.0E
[
288FEA
]
*NOT sel
ectable*
Figure 35 Option access key