Seitenansicht 64
4-15
Working with Disks
The CLI also lets you renumber (assign another ID to) a container.
See Chapter 9, Modifying Containers, for a description of how to
renumber a container.
Displaying a Container’s Type
The container type attribute indicates if a partition resides in a
volume set, stripe set, RAID-5 set, etc.
To display the type of container in which the partition resides, use
the disk show partition command, as in the following
example. In the example, the Container Type column indicates the
container type on SCSI devices (2,1,0) and (2,2,0). In this case the
containers are Volume sets.
HPN0> disk show partition
Executing: disk show partition
Scsi Partition Container MultiLevel
C:ID:L Offset:Size Num Type Num Type R/W
------ ------------- --- ------ --- ------ ---
2:01:0 64.0KB: 15.0MB 0 Volume 0 None RW
See the Command Line Interface Reference Guide for a description of
other Container Type values.
Displaying a Multilevel Container’s ID
The multilevel container ID attribute indicates the ID of a
multilevel container that the partition is associated with, if any. A
multilevel container is a logical disk created from one or more
single-level containers. The multilevel ID number is automatically
assigned to a multilevel container when you create it by using one of
the multi-level container create commands.
To display the ID of a multilevel container, use the disk show
partition command, as in the following example. In the example,
the MultiLevel Num column shows that 0 is the multilevel
container ID of a stripe set of mirror sets.
HPN0> disk show partition
Executing: disk show partition
Scsi Partition Container MultiLevel
Seitenansicht 64