Hp ProLiant SL2500 Scalable System Bedienungsanleitung Seite 82

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 117
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 81
CLI commands 82
Set serial
Command:
SET SERIAL <baud rate>
Description:
o Configure the serial console baud rate.
o Serial access to the CLI will be by default 115200 bits/s, no parity, 8 data bits, and one stop bit
(“115200 N 8 1”). You can configure these parameters through the CLI.
o Valid baud rates are 300, 1200, 2400, 4800, 9600, 14400, 19200, and 115200.
Set syslog
Command:
SET SYSLOG {<ip_address>|NONE}
Description:
Sets or clears the sending of HP APM log messages to a remote syslog server. Local logging is
unaffected.
Set time
Command:
SET TIME <month> <day> <year> <hour> <minute>
where:
<month> is the month.
<day> is the day.
<year> is the year.
<hour> is the hour, in 24-hour format. For example, enter 3:00 p.m. as 15.
<minute> is the minute.
HP APM does not automatically adjust for Daylight Savings Time.
The time remains on this setting until you issue the RESET FACTORY command.
Description:
o Sets the system time on the battery-backed clock.
o All five parameters must be present. The hour parameter must be in 24-hour format.
Set timeout
Command:
SET TIMEOUT {<timeout_value> | NONE}
where:
<timeout_value> is the session timeout value measured in seconds. For example, to set a 30-second
session timeout, enter:
Seitenansicht 81
1 2 ... 77 78 79 80 81 82 83 84 85 86 87 ... 116 117

Kommentare zu diesen Handbüchern

Keine Kommentare