Network
The following table describes the options available in the Network tab of the RGS Sender Conguration tool.
The corresponding property in the rgsenderconfig le is noted for reference.
Option Description
Error timeout (milliseconds) Sets the time in milliseconds that RGS Sender will wait before ending
the connection after failing to detect RGS Receiver.
Corresponding property:
Rgsender.Network.Timeout.Error
Listen for RGS connections on all network interfaces When enabled, RGS Sender will listen for connections on all network
interfaces.
Corresponding property:
Rgsender.Network.IsListenOnAllInterfacesEnabled
Listen to a specic network interface Species which network interfaces RGS Sender will listen for
connections on.
See RGS Sender network interface binding on page 66 for more
information on how to determine the value that corresponds with each
network interface.
NOTE: This option is not available if the Listen for RGS connections on
all network interfaces option is enabled.
Corresponding property:
Rgsender.Network.Interface.N.IsEnabled
NOTE: If setting the property manually, replace N with the number of
the network interface.
Listen to a specic range of IP addresses Species the range of IP addresses that RGS Sender will listen for
connections on. A network interface must be enabled using the Listen
to a specic network interface option, and its IP address must be in the
specied range.
NOTE: This option is not available if the Listen for RGS connections on
all network interfaces option is enabled.
Corresponding property:
Rgsender.Network.AllowIpAddressSubnet
RGS Sender network port Species the port to use for communication between RGS Sender and
RGS Receiver.
IMPORTANT: This setting must match the port setting on RGS
Receiver.
Corresponding property:
Rgsender.Network.Port