Table 96 SSB codes that are returned by raidcom modify port -port_speed command (continued)
raidcom modify port -port_speed
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
The other than "P-to-P (point to point)" cannot be specified when
specifying a topology of the package for Fibre Channel over
Ethernet.
05A7B955ExecutingCMDRJE
The command device being used at the local RAID Manager
exists under the port.
1039B955ExecutingCMDRJE
The program product is not installed.104FB955ExecutingCMDRJE
Invalid host speed is set for 4Gbps fibre adapter. The available
host speeds are AUTO, 1G, 2G, and 4G only.
113DB955ExecutingCMDRJE
Invalid host speed is set for 8Gbps Fibre Adapter. The available
host speeds are AUTO, 2G, 4G, and 8G only.
113FB955ExecutingCMDRJE
The other than "10G" cannot be specified when specifying a
host speed of the package for Fibre Channel over Ethernet.
11A5B955ExecutingCMDRJE
Table 97 SSB codes that are returned by raidcom modify port -port_attribute command
raidcom modify port -port_attribute
DescriptionError codeExecuting/
Asynchronous
Error message
SSB2SSB1
Invalid package84042E00ExecutingCMDRJE
The operation cannot be done because another application, for
example Remote Web Console and SVP, is used.
80012E10ExecutingCMDRJE
The specified port is blocked.84002E10ExecutingCMDRJE
There is a pair for Continuous Access Synchronous/Continuous
Access Journal that is used the specified port.
84022E10ExecutingCMDRJE
There is a pair for Continuous Access Synchronous/Continuous
Access Journal that is used the specified port.
84032E10ExecutingCMDRJE
The storage system is in the state of start-up. Wait for a while,
then retry the operation.
800D2E11ExecutingCMDRJE
The specified port is not installed.84002E20ExecutingCMDRJE
There is a path for Continuous Access Synchronous/Continuous
Access Journal in the specified port.
84032E30ExecutingCMDRJE
There is an external VOL path in the specified port.84062E30ExecutingCMDRJE
There is a path for Continuous Access Synchronous/Continuous
Access Journal in the specified port.
84072E30ExecutingCMDRJE
There is a path for Continuous Access Synchronous/Continuous
Access Journal in the specified port.
84082E30ExecutingCMDRJE
An LU path has been defined.84092E30ExecutingCMDRJE
An internal error occurred.84FC2ED0ExecutingCMDRJE