Table 77 SSB codes returned by raidcom add snapshot (continued)
raidcom add snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
The command ends abnormally because an unmounted
volume is specified as the S-VOL of a Fast Snap or Snapshot
pair.
000B2E20ExecutingCMDRJE
The command ends abnormally because the blocked
volume is specified as the S-VOL of a Fast Snap or Snapshot
pair.
000C2E20ExecutingCMDRJE
The command ends abnormally because the volume in
formatting operation is specified as the S-VOL of a Fast
Snap or Snapshot pair.
000D2E20ExecutingCMDRJE
The command ends abnormally because the shared
memory (FC, TPF, or Extension1) is not expanded for
necessary capacity.
81072E21ExecutingCMDRJE
The command ends abnormally because the shared
memory (SS1 or more) is not expanded for necessary
capacity.
81082E21ExecutingCMDRJE
A Fast Snap or Snapshot pair cannot be created due to
one of the following reasons:
81092E21ExecutingCMDRJE
The shared memory is not expanded for necessary
capacity.
It is in the initializing process.
The program product is not installed.90102E21ExecutingCMDRJE
A pair cannot be created because the volume is already
used in the S-VOL of a Fast Snap or Snapshot pair is
specified as the P-VOL.
00762E30ExecutingCMDRJE
A pair cannot be created because the volume is already
used in the P-VOL of a Fast Snap or Snapshot pair is
specified as the S-VOL.
00772E30ExecutingCMDRJE
A pair cannot be created because the volume is already
used in the S-VOL of a Fast Snap or Snapshot pair is
specified as the S-VOL.
00782E30ExecutingCMDRJE
The command ends abnormally because the volume other
than OPEN-V is specified as the P-VOL of a Fast Snap or
Snapshot pair.
007A2E30ExecutingCMDRJE
A pair cannot be created because the volume that is set
the command device is specified as the P-VOL of a Fast
Snap or Snapshot pair.
007B2E30ExecutingCMDRJE
The command ends abnormally because the volume other
than OPEN-V is specified as the S-VOL of a Fast Snap or
Snapshot pair.
007C2E30ExecutingCMDRJE
A pair cannot be created because the volume that is set
the command device is specified as the S-VOL of a Fast
Snap or Snapshot pair.
007D2E30ExecutingCMDRJE
The command ends abnormally because the volume that
has no path definition is specified as the P-VOL of a Fast
Snap or Snapshot pair.
007E2E30ExecutingCMDRJE
238 Troubleshooting