Table 77 SSB codes returned by raidcom add snapshot (continued)
raidcom add snapshot
DescriptionError codeExecuting/AsyncError message
SSB2SSB1
The command ends abnormally because the volumes in
which the number of slots is different are specified as the
P-VOL of a Fast Snap or Snapshot pair and S-VOL.
00312E10ExecutingCMDRJE
A pair cannot be created because the Thin Provisioning
V-VOL is specified as the S-VOL of a Fast Snap or Snapshot
pair.
00322E10ExecutingCMDRJE
The command ends abnormally because the Business Copy
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.
00332E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
source volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
00342E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
target volume is specified as the P-VOL of a Fast Snap or
Snapshot pair.
00352E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
reserved volume is specified as the P-VOL of a Fast Snap
or Snapshot pair.
00362E10ExecutingCMDRJE
The command ends abnormally because the P-VOL of a
Business Copy pair is specified as the S-VOL of a Fast Snap
or Snapshot pair.
00372E10ExecutingCMDRJE
The command ends abnormally because the S-VOL of a
Business Copy pair is specified as the S-VOL of a Fast Snap
or Snapshot pair.
00382E10ExecutingCMDRJE
The command ends abnormally because the Business Copy
reserved volume is specified as the S-VOL of a Fast Snap
or Snapshot pair.
00392E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
source volume is specified as the S-VOL of a Fast Snap or
Snapshot pair.
003A2E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
target volume is specified as the S-VOL of a Fast Snap or
Snapshot pair.
003B2E10ExecutingCMDRJE
The command ends abnormally because the Auto LUN
reserved volume is specified as the S-VOL of a Fast Snap
or Snapshot pair.
003C2E10ExecutingCMDRJE
A Fast Snap or Snapshot pair cannot be created because
the volume of Continuous Access Journal for the delta
003D2E10ExecutingCMDRJE
resync is specified as the P-VOL of a Fast Snap or Snapshot
pair.
A Fast Snap or Snapshot pair cannot be created because
the volume of Continuous Access Journal for the delta
003E2E10ExecutingCMDRJE
resync is specified as the S-VOL of a Fast Snap or Snapshot
pair.
The command ends abnormally because the Quorum disk
is specified as the P-VOL of a Fast Snap or Snapshot pair.
003F2E10ExecutingCMDRJE
The command ends abnormally because the Quorum disk
is specified as the S-VOL of a Fast Snap or Snapshot pair.
00402E10ExecutingCMDRJE
Error messages and error codes 235