Hp XP Continuous Access Software Bedienungsanleitung Seite 170

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 412
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 169
170 HP StorageWorks Disk Array XP RAID Manager: User’s Guide
–swap[s|p](CA only) The –swaps option is executed from the
S-VOL when there is no host on the P-VOL side to
help. A remote host must be connected to the S-VOL.
Typically executed in PSUS (SSWS) state (after a
horctakeover) to facilitate fast failback without
requiring a full copy.
Unlike –swaps, –swapp requires the cooperation of
hosts at both sides. It is the equivalent of
–swaps,
executed from the original P-VOL side.
For both –swaps and –swapp, the delta data from the
original S-VOL becomes dominant and is copied to the
original P-VOL, then the P-VOL/S-VOL designations
are swapped.
The application can continue to run at the remote
failover site during this operation. At completion, the
remote failover site will own the P-VOL. When
desired, a very fast
horctakeover will allow a fast
failback of the application from the recovery site to the
original site.
The following figure describes the –swap[s|p]
operation. The left side of the diagram shows T0 (time
zero) for both the P-VOL and S-VOL, before command
execution. The right side shows T1, after command
execution.
P-VOL
S-VOL
Altered Data
R or R/W
R/W
NEW_
SVOL
NEW_
PVOL
R/W
R
pairresync -swaps on SVOL
or
pairresync -swapp on PVOL
T
T1
T0 T1 situation
T1
T0
Seitenansicht 169
1 2 ... 165 166 167 168 169 170 171 172 173 174 175 ... 411 412