B.78
stoprcopy
Remote Copy User’s Guide InForm OS Version 2.3.1
EXAMPLES
The following example disables the Remote Copy functionality of all Remote Copy volume
groups:
NOTES
If the -stopgroups option is not used, all groups must already be stopped.
An older version of this command provided specifiers to disable the primary or backup
systems. These specifiers were deprecated in InForm OS release 2.2.3.
Unless the -stopgroups option is used, the command will fail if there are any Remote
Copy groups that are started. If the
-clear option has been used, the configuration is
completely erased. Consequently, Remote Copy operations can not be restarted using only
the
startrcopy command. The configuration must be rebuilt. Therefore, the -clear
option requires confirmation with the
-f option, the TPDFORCE environment variable, or
by interactively typing,
y. Refer to the InForm OS CLI Administrator’s Manual for
information about using environment variables.
cli% stoprcopy -stopgroups