Refer to Table 50 to determine the location of each temperature sensor.
T able 50 Temperature sensor element numbering
Sensor
Sensor location
Sensor
Sensor location
01.
Power Supply 1 Exhaust
10.
Drive Bay 7
02.
Power Supply 2 Exhaust
11.
Drive Bay 8
03.
EMU
12. Drive Bay 9
04.
Drive Bay 1
13. D rive B ay 10
05. Drive Bay 2
14 .
Drive Bay 11
06. Drive Bay 3
15.
Drive Bay 12
07 .
Drive Bay 4
16. Drive Bay 13
08.
Drive Bay 5 17.
Drive Bay 14
09. Driv e Bay 6
The following sections list the temperature condition reports and the default temperature thresholds. Use HP
Command View EVA to view the temperature sensor ranges for the disk drives, EMU, and power supplies.
0.4.en.01 N
ONCRITICAL condition—High temperature
This condition report indicates that an element temperature is approaching, but has not reached, the high
temperature CRITICAL threshold. Continued op eration under these conditions may result in a CRITICAL
condition.
This condition report remains active until the p roblem i s corrected.
Complete the following procedure to correct this problem.
1. Record all six characters of the condition report.
2. Ensure that all elements are properly installed to maintain proper air ow.
3. Ensure tha
t nothing is obstructing the air ow at either the front of the enclosure or the rear of
the blower.
4. Ensure that both blowers are operating properly (the indicators are on) and neither blower is
operatin
gathighspeed.
5. Verify t
hat the am bient temperature range is +10 °C to +35 °C (+50 °F to +95 °F). Correct the
ambient conditions.
6. Observe the EMU to ensure the error is corrected.
7. If unabl
e to correct the problem, contact your authorized ser vice representative.
0.4.en.02CRITICALconditionHightemperature
This condition report indicates that an element temperature is above the high temperature CRITICAL
threshold. Continued operation under these conditions may result in element failure and may reduce an
element MTBF. This condition report remains active until the problem is corrected.
Complete the following procedure to correct this problem.
1. Record all six characters of the condition report.
2. Ensure that all elements are properly installed to maintain proper air ow.
3. Ensure that nothing is obstructing the air ow at either the front of the enclosure or the rear of
the blower.
4. Ensure that both blowers are operating properly (the indicators are on) and neither blower is
operating at high speed.