Hp Smart Update Manager (User Guide) Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Software Hp Smart Update Manager (User Guide) herunter. HP Smart Update Manager (User Guide) User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 82
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HP Smart Update Manager
User Guide
Abstract
This guide is intended for individuals familiar with the configuration and operation of Microsoft Windows, Windows Server 200
3 and 2008, Linux,
smart components, and deployment of firmware and software. Because
of the risk of data loss, only individuals experienced with using firmware and
software should implement the procedures.
Part Number: 613175-005
September 2011
Edition: 5
Seitenansicht 0
1 2 3 4 5 6 ... 81 82

Inhaltsverzeichnis

Seite 1 - User Guide

HP Smart Update Manager User Guide Abstract This guide is intended for individuals familiar with the configuration and operation of Microsoft Window

Seite 2

Introduction 10 o libxcb-1.5-1.el6.i686.rpm o libXau-1.0.5-1.el6.i686.rpm o libXrender-0.9.5-1.el6.i686.rpm o libXrandr-1.3.0-4.el6.i686.rpm o l

Seite 3 - Contents

Introduction 11 HP SUM version Delivered with Support and limitations 8.50 • HP ProLiant Support Pack for Linux 8.50 packs 4.0.2 • HP Smart Updat

Seite 4 - Contents 4

Introduction 12 Scenario Description HP SUM command HP deliverable • Do not require scripting • Want to select the components to be installed S

Seite 5 - Contents 5

Introduction 13 Scenario Description HP SUM command HP deliverable (use the HP Smart Update Firmware DVD with embedded HP SUM to deploy firmware

Seite 6 - Introduction

Introduction 14 HP SUM stores host and group information from session to session. However, user names, passwords, and existing credentials are not s

Seite 7 - Minimum requirements

Introduction 15 Firmware Types Supported by HP SUM HP StorageWorks MDS 600 enclosure firmware Yes MSA 2000 firmware (P2x00 firmware) No D2600/D2700

Seite 8

HP SUM User Interface 16 HP SUM User Interface Deployment scenarios HP SUM deploys firmware and software on a local host or one or more remote hosts

Seite 9 - • RHEL6 graphical mode

HP SUM User Interface 17 Source selections Use the Source Selections screen to: • Select repositories that contain updates • Add repositories •

Seite 10

HP SUM User Interface 18 • Name—This field displays the repository name. Select the repositories you want to use by checking the box next to the re

Seite 11 - Deployment from HP SUM

HP SUM User Interface 19 4. Enter the User ID (if necessary). 5. Enter the Password (if necessary). 6. Click OK. Using multiple repositories HP S

Seite 12

© Copyright 2011 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties

Seite 13 - Update Firmware DVD

HP SUM User Interface 20 NOTE: If you select firmware or software only, you might not have any updates to apply to a device on the Select Bundles

Seite 14

HP SUM User Interface 21 by the component. The configuration is stored within the component and is propagated to all targets. If the optional config

Seite 15

HP SUM User Interface 22 Select targets The Select Targets screen, allows you to do the following: • Select targets (for example, servers or enclo

Seite 16 - HP SUM User Interface

HP SUM User Interface 23 The table displays the following target information: • Check box—Targets with selected checkboxes are updated. Click the c

Seite 17 - Source selections

HP SUM User Interface 24 Target types Supported target types include: • Server–a local host or a remote server. • iLO • Onboard Administrator •

Seite 18 - Set Proxy Server options

HP SUM User Interface 25 6. Click OK to save and close the dialog box. 7. Click Done. 8. In the Select Targets screen table, the Status field will

Seite 19 - Add Repository

HP SUM User Interface 26 • Schedule updates • Select bundles to install on bundles and/or targets • Select components to install to bundles and/o

Seite 20 - Configure Components

HP SUM User Interface 27 Abort installation Click Abort Installation to complete the installation of the current component and then abort the instal

Seite 21 - HP SUM User Interface 21

HP SUM User Interface 28 3. Check each component that you want to update on the selected target. If there is a dependency failure, click Failed Depe

Seite 22 - Select targets

HP SUM User Interface 29 that caused the warning might cause more serious problems. To continue without resolving the warnings, select Ignore Warnin

Seite 23 - Dependency checking

Contents 3 Contents Introduction ...

Seite 24 - Enter Target Credentials

HP SUM User Interface 30 1. Click Schedule Update. 2. Click Create Schedule, type a schedule description, and then click OK. 3. Select the targets

Seite 25 - Install updates

Scripted deployment 31 Scripted deployment Command-line interface The HP SUM command-line interface enables you to script custom installations. Com

Seite 26 - Installing updates

Scripted deployment 32 Command-line arguments HP SUM 5.0.0 recognizes the following command-line arguments. These arguments can be used to pre-popul

Seite 27 - Select bundles

Scripted deployment 33 Installation options Description "group_name" Manager graphical user interface. /b[undle] <bundle_to_install>

Seite 28 - Select devices

Scripted deployment 34 Installation options Description used, the AMS components are required, but the WMI components are optional. /use_wmi This a

Seite 29 - Schedule Updates

Scripted deployment 35 Reboot options Description • All components selected for installation are successfully installed. • At least one of the in

Seite 30 - Generate and View Reports

Scripted deployment 36 Targets Description /oa_password This argument provides the password credential for OA associated with VC specified with &qu

Seite 31 - Scripted deployment

Scripted deployment 37 Using input files Description /inputfile “filename” This argument enables you to script the deployment of firmware and soft

Seite 32 - Command-line arguments

Scripted deployment 38 Command G7 and earlier /use_ams/use_wmi WBEM and SNMP /use_wmi/use_snmp WBEM and SNMP /use_ams/use_wmi/use_snmp WBEM and SNM

Seite 33

Scripted deployment 39 o HP System Management Homepage for Windows (cp008257.exe) • HP Smart Update Manager o Defined groups: Management Servers—T

Seite 34 - Reboot options Description

Contents 4 Generate a Report ...

Seite 35

Scripted deployment 40 Return codes HP SUM has consolidated return codes from Linux and Windows® smart components into a new, enhanced return code m

Seite 36

Scripted deployment 41 Error level Meaning 1 The installation of the deliverable is successful. Reboot is required for the deliverable to be enable

Seite 37 - Switch update commands

Scripted deployment 42 Command-line usage of input file The form for the HP SUM command line using an input file is hpsum -inputfile <filename>

Seite 38 - Command-line examples

Scripted deployment 43 Error reporting If errors are encountered in the input file, HP Smart Update Manager exits with a return value of -2 (bad par

Seite 39 - Scripted deployment 39

Scripted deployment 44 Parameter Description Possible values SKIPTARGET This parameter defines the behavior when a remote target has an existing H

Seite 40 - Return codes

Scripted deployment 45 Parameter Description Possible values installation. Do not use the /romonly parameter with the /softwareonly parameter. SOF

Seite 41 - Input files

Scripted deployment 46 Parameter Description Possible values location. * For Windows components, the default location is %SYSTEMDRIVE%\CPQSYSTEM\h

Seite 42 - File encoding

Scripted deployment 47 Parameter Description Possible values CMASTARTSTORAGEAGENT This parameter determines whether the HP Insight Systems Manager

Seite 43 - Input file parameters

Scripted deployment 48 Parameter Description Possible values subnets to use for its web servers. The IP-BINDING parameter must be set to yes for t

Seite 44

Scripted deployment 49 Parameter Description Possible values • TrustByAll—HP does not recommend using this value because of possible negative sec

Seite 45

Contents 5 Troubleshooting HP Smart Update Manager in IPv6 Windows Server 2003 environment ... 70 Troubleshooting HP Smart Upda

Seite 46 - NO (do not start the

Scripted deployment 50 COMPONENTSLIST = cp001234.exe, cp001235.exe BUNDLESLIST = bp001234.xml ALLOWUPDATEBUNDLE = YES SKIPTARGET = NO IGNOREERRORS =

Seite 47

Scripted deployment 51 SKIPTARGET = NO SOURCEPATH = C:\fwcd\firmware-8.70-0\hp\swpackages [GROUPS] HOST=winserver UID=Userid PWD=password [END] Exam

Seite 48

Scripted deployment 52 Report type Description Report file information* /report This argument generates a report listing, a target summary, and h

Seite 49

Scripted deployment 53 The following figure illustrates the HP SUM report in HTML format.

Seite 50 - Scripted deployment 50

Scripted deployment 54 The following figure illustrates the HP SUM Inventory report in HTML format.

Seite 51 - Reports

Scripted deployment 55 The following figure illustrates the HP SUM Firmware report in HTML format.

Seite 52

Advanced topics 56 Advanced topics Configuring IPv6 networks with HP Smart Update Manager Starting with HP Smart Update Manager version 3.2.0, you c

Seite 53 - Scripted deployment 53

Advanced topics 57 HKEY_LOCAL_MACHINE\System\CurrentControlSet\Services\LanmanServer\Parameters 3. On the Edit menu, click Add Value. 4. Add the f

Seite 54 - Scripted deployment 54

Advanced topics 58 After you connect to the target server, all other HP Smart Update Manager functions work identically. Log files for IPv6 hosts ar

Seite 55 - Scripted deployment 55

Advanced topics 59 IPv6 addresses can be passed to HP Smart Update Manager in command line arguments or using the HP Smart Update Manager user inter

Seite 56 - Advanced topics

Introduction 6 Introduction HP SUM overview HP SUM is a technology included in many HP products for installing and updating firmware and software co

Seite 57 - Advanced topics 57

Advanced topics 60 Limitations of IPv6 for Linux The only current limitation of HP Smart Update Manager in a Linux IPv6 environment is that all remo

Seite 58 - Configuring IPv6 for Linux

Troubleshooting 61 Troubleshooting Recovering from a failed ROM upgrade Recovering from a failed system ROM upgrade Use redundant ROM or ROMPaq to r

Seite 59 - Advanced topics 59

Troubleshooting 62 6. Power up the server. The server generates one long beep and two short beeps to indicate that it is in disaster recovery mode.

Seite 60 - Advanced topics 60

Troubleshooting 63 Recovering from an installation failure Collecting trace directories HP SUM generates a set of debug trace logs located in the %T

Seite 61 - Troubleshooting

Troubleshooting 64 Log Files Function screen. Hpsum_detail_log.txt This file contains the log data of the components. hpsum_execution_log_<date

Seite 62 - Lights-Out management ROMs

Troubleshooting 65 • Ensure your workstation does not have an existing connection to the ADMIN$ share on the target IP address. If it does, it prev

Seite 63 - Collecting trace directories

Troubleshooting 66 Recovering from a loss of Linux remote functionality Configuring firewall settings When the Unable to Access Host message appears

Seite 64

Troubleshooting 67 Enabling ports in HP Smart Update Manager The ports that HP SUM uses cannot be configured. When HP SUM initiates communications t

Seite 65 - HP SUM hangs during boot

Troubleshooting 68 Ports 80 or 63000-63005 For Integrity servers and c-Class OA, port 80 must be opened on the local system for the remote system to

Seite 66 - Windows

Troubleshooting 69 Recovering from operating system limitations when using a Japanese character set Displaying the user-specified reboot message usi

Seite 67

Introduction 7 • Support for updating firmware on network-based targets such as the OA, iLO 2/iLO 3 through Network Management Port, and VC Etherne

Seite 68 - Port Description

Troubleshooting 70 Troubleshooting HP Smart Update Manager in IPv6 networks If HP Smart Update Manager cannot connect to the remote server, you migh

Seite 69 - Troubleshooting 69

Troubleshooting 71 Troubleshooting HP Smart Update Manager in IPv6 Windows Server 2008 environment To validate that the IPv6 network is configured c

Seite 70 - Server 2003 environment

Troubleshooting 72 HP SUM found new hardware message During the discovery progress, HP SUM might display the following pop-up message: Found New Har

Seite 71 - Server 2008 environment

Troubleshooting 73 HP SUM displays No components found in the selected repository(ies) message The No components found in the selected repository(ie

Seite 72 - Troubleshooting 72

Troubleshooting 74 4. Select the Activity Log tab. As displayed in the following image, in the Message column, notice the entry similar to the follo

Seite 73 - 2. Select Manage Features

Troubleshooting 75 9. From the screen image, use the following settings for the new firewall rules on your system. 10. Click OK to ensure new fire

Seite 74

Troubleshooting 76 Performing these steps allows HP SUM to function, although after a period of time (ranging from minutes to hours), McAfee disable

Seite 75 - Restart HP SUM

Technical support 77 Technical support Reference documentation • To download the ProLiant Firmware Maintenance CD, Smart Update Firmware DVD, Smart

Seite 76 - HP SUM is not supported

Technical support 78 • SUSE Linux (http://www.novell.com/linux) HP contact information For United States and worldwide contact information, see th

Seite 77 - Technical support

Acronyms and abbreviations 79 Acronyms and abbreviations AMS agentless management services CLI Command Line Interface DNS domain name system FPGA

Seite 78 - HP contact information

Introduction 8 manner, you must have the user name and password available for each remote server available. Alternatively, you can use a domain acco

Seite 79 - Acronyms and abbreviations

Acronyms and abbreviations 80 POST Power-On Self Test PSP HP ProLiant Support Pack RBSU ROM-Based Setup Utility RILOE II Remote Insight Lights-Ou

Seite 80

Index 81 A advanced topics 56 arguments 32 authorized reseller 77, 78 B blocked HP Smart Update Manager, recovering from 66 bundle filter op

Seite 81 - Index 81

Index 82 M maximizing a window to single display 73 minimum requirements 7 minimum requirements for Linux servers 8 minimum requirements for W

Seite 82 - Index 82

Introduction 9 o e2fsprogs-32bit • For SLES 11 x86 servers: o libstdc++33-3.3.3-11.9.i586 or later o libnl (required for QLogic and Emulex driver

Kommentare zu diesen Handbüchern

Keine Kommentare