HP Smart Update Manager User Guide
Abstract
This document describes how to use HP SUM to apply firmware updates to HP ProLiant and HP Integrity servers, and apply
software updates to HP ProLiant servers. This document is intended for individuals who understand the configuration and
operations of Microsoft Windows, Windows Server, Linux, smart components, and the risk of data loss from performing updates.
HP Part Number: 613175-008
Published: October 2012
Edition: 8
Seitenansicht 0
1 2 3 4 5 6 ... 78 79

Inhaltsverzeichnis

Seite 1 - Abstract

HP Smart Update Manager User GuideAbstractThis document describes how to use HP SUM to apply firmware updates to HP ProLiant and HP Integrity servers,

Seite 2

SupportedComponentNoSAS and SATA hard drive firmware behind non-SmartArray controllersYesEmulex, QLogic, and Brocade Fibre Channel HBA firmwareYesTape

Seite 3 - Contents

Deployment modesThe following key terms are used when using HP SUM to deploy updates:DefinitionTermThe installation runs on the physical hardware you

Seite 4 - 4 Contents

The following table describes when typical HP SUM deployment scenarios are used.Used whenScenarioGraphical deployment on a local host• You are not fam

Seite 5 - Contents 5

To enable firmware updates without the need to type in the TPM password on each server, theBitLocker Drive Encryption must be temporarily disabled. Di

Seite 6 - 1 Introduction

2 Using the HP SUM GUIKeyboard supportThe HP SUM GUI has accelerator keys that enable you to manage and control common tasksquickly. To ensure proper

Seite 7 - Deploying HP SUM

components are available for selection. The components are not downloaded fromftp.hp.com to a target until the Install button is clicked unless the co

Seite 8

Using multiple repositoriesHP SUM allows you to select one or more repositories when selecting components to be installed.You can have a different fil

Seite 9 - ◦ HP SPP

\repository• UNC path:\\myfileserver\repository\\10.1.1.1\myrepos4. Click OK.Editing the repositoryYou can edit a repository to change its name or loc

Seite 10

2. Follow the instructions when the Item Configuration screen appears.3. When you finish configuring all the components, click OK to return to the Sou

Seite 11 - Deployment scenarios

7. Select the check box for the updates you want to use from the Baseline Repositories list .8. Click Save and Continue to save your baseline. For mor

Seite 12 - Choosing HP SUM or HP SIM

© Copyright 2009, 2012 Hewlett-Packard Development Company, L.P.The information contained herein is subject to change without notice. The only warrant

Seite 13

Selecting the targetsThe Select Targets screen automatically detects the local system running HP SUM and adds it tothe targets list. To find new targe

Seite 14 - 2 Using the HP SUM GUI

Inter-target dependencyHP SUM finds potential targets by checking the OA host server list for all targets you add. HP SUMasks you if you want to add t

Seite 15 - Source selections 15

2. Select IP Address Range, Port Address, or LDAP Scan for Remote Targets, and then click OK.• IP Address–Enables you to search a range of IP addresse

Seite 16 - Adding the repository

8. In the Select Targets screen table, the Status field displays progress messages as HP SUMverifies the credentials you entered.NOTE: HP Integrity se

Seite 17 - Editing the repository

Pending firmware updates for iLO (HP Integrity servers only)If you update a previously updated Integrity server via iLO but did not power down and reb

Seite 18 - 18 Using the HP SUM GUI

This screen appears after HP SUM completes the dependency checks for each target. The statuscolumn notifies you whether each target has updates availa

Seite 19 - Saving a custom baseline

Viewing failed dependenciesIf a failed dependency occurs, you must resolve it by ensuring the prerequisite libraries or theappropriate software or fir

Seite 20 - Selecting the targets

Selecting componentsUse this screen to install individual smart components that are not contained in a bundle. You canchoose the devices to update, an

Seite 21 - Target types

Viewing firmware detailsYou can view the firmware detail screen from these screens:• Review/Install Updates• Select Bundles• Select ComponentsTo open

Seite 22 - Entering target credentials

3. Do one of the following:• Click Downgrade or Rewrite, depending on whether you want to downgrade the firmwareversion, or overwrite the current firm

Seite 23 - Managing groups

Contents1 Introduction...6HP SUM overview...

Seite 24 - 24 Using the HP SUM GUI

Generating and viewing reportsYou can generate a report file in HTML, XML, or CSV format that details the repository contents,target firmware, target

Seite 25 - Aborting an installation

3 Using scripts to deploy updatesCommand-line interfaceYou can use the HP SUM command-line interface to script custom installations.Command-line synta

Seite 26 - Selecting bundles

The following table shows what updates occur if no switches are currently installed.Gen8 serversG7 and earlier serversCommandAMSSNMPno switchesNothing

Seite 27 - Selecting devices

The following table shows what updates occur if AMS switches are currently installed.Gen8 serversG7 and earlier serversCommandAMSN/Ano switchesAMSN/A/

Seite 28 - Installation options

DescriptionInstallation optionscomponent installation fails, and an error message writesto the log file.Failed dependencies are not reported to the us

Seite 29 - Scheduling updates

DescriptionInstallation optionscommand line. If there are no bundles specified on thecommand line, and multiple bundles are in the directory,the /use_

Seite 30 - Viewing a report

DescriptionInstallation optionsThis filter switch allows you to see only the firmwarecomponents needed for installation. When you are using/romonlythi

Seite 31 - Command-line interface

DescriptionOverriding errorsThis command is for HP Integrity servers only.Use these arguments if you do not use the/partition_only argument. If you do

Seite 32

DescriptionTargetsConnect Ethernet or Fibre Channel Module for c-ClassBladeSystem, or BladeSystem OA.When two OAs are in an enclosure, this argument s

Seite 33 - Command-line arguments

DescriptionLog fileslog<netAddress> and the redirected location is<path>\hp\log\<netAddress>.• For Linux components, the default loc

Seite 34

Generating and viewing reports...30Generating a Report...

Seite 35

DescriptionSuperdome 2 server commandsExample: /update_type PARTITIONSUse this argument when the /update_type argument isPARTITIONS. This argument spe

Seite 36

hpsum /use_latest /allow_non_bundle_components /silentResults: All software components and firmware components from the update bundle, which HPSUM det

Seite 37

In Linux, the negative return codes are reported. These return codes are determined by subtractingthe negative value from 256.TextWindowsLinuxValueRet

Seite 38

MeaningError levelThe installation was not attempted because the version tobe installed matches the version already installed.2The installation was no

Seite 39

Input file format and rulesThe input file is divided into two sections:• ConfigurationThe configuration section starts from the beginning of the file

Seite 40

Input file parametersPossible valuesDescriptionParameterYES, NOThis parameter causes the installationto run silently without GUI or consoleSILENToutpu

Seite 41 - Return codes

Possible valuesDescriptionParameterversions of the same component thatmight have shipped with the bundles.YES, NODefines the behavior when a remotetar

Seite 42 - Multi-target servers:

Possible valuesDescriptionParameterYES, NOSpecifies that components that useSNMP protocol, are available to beselected for installation.USESNMPThese c

Seite 43 - Input files

Possible valuesDescriptionParameterThe default of OmitHost causes thehost to be put in a failure state, andno installation is attempted on it.OmitComp

Seite 44 - Error reporting

Possible valuesDescriptionParametermanagement station. You can specifymultiple strings separated by a space.(Applies to Linux PSP only.)IP address, DN

Seite 45 - Input file parameters

Automatic reboot does not occur when using the user-specified reboot message with a Japanesecharacter set on Windows...

Seite 46

Possible valuesDescriptionParameterHPVCAVCRMLOGIN parameter.(Applies to Linux PSP only.)YES, NO (default)HP Systems Management Homepage(hpsmh) uses th

Seite 47

Possible valuesDescriptionParameterThis parameter is ignored unless theIP-RESTRICTED-LOGINS parameteris set to yes.HP Systems Management Homepageuses

Seite 48

Possible valuesDescriptionParameterThe hp_qla2x00 QLogic FibreChannel Driver uses this parameter toHPQLA2X00FO• SinglePath• SecurePathdetermine the fa

Seite 49

BUNDLESLIST = bp001234.xmlALLOWUPDATEBUNDLE = YESSKIPTARGET = NOIGNOREERRORS = ServerNotFound, FailedDependenciesSOURCEPATH = c:\pkgsource1USELATEST =

Seite 50

PWD=password[END]ExampleSILENT = YESIGNOREERRORS = ServerNotFound,BadPassword, FailedDepedenciesSKIPTARGET = NOSOURCEPATH = C:\ fwcd\firmware-8.70-0\h

Seite 51

ReportsHP SUM generates three types of reports about the specified system or repository. HP SUM generatesthese reports by using the command-line argum

Seite 52

commands. For more information about downloading and installing HP SUM as an RPM, see thedocument Linux best practices using HP Service Pack for ProLi

Seite 53 - Input files 53

4 Advanced topicsConfiguring IPv6 networksYou can deploy to remote targets in IPv6-based networks for Windows and Linux target servers.Using HP SUM wi

Seite 54

IPv6 addresses can be passed to HP SUM in command line arguments or using the HP SUM userinterface. In the HP SUM user interface, you can add a remote

Seite 55

The only current limitation of HP SUM in a Linux IPv6 environment is that all remote target Linux-basedservers must have the iptables-ipv6 RPM file in

Seite 56

1 IntroductionHP SUM overviewHP SUM is a technology included in many HP products for installing and updating firmware andsoftware on HP ProLiant serve

Seite 57 - 4 Advanced topics

Table 3 HP SUM Linux network portsDescriptionPortsEstablishes a connection to the remote Linux server via SSH. For Integrity servers,HP SUM uses this

Seite 58 - Configuring IPv6 for Linux

5 TroubleshootingInstallation issuesComponents do not appear on the Select Items to Install screen or do not deploy fromthe silent console modeSolutio

Seite 59 - Network ports used by HP SUM

NOTE: Exit HP SUM before running the GatherLogs utility.FunctionDebug Trace FilesContains operations manager trace data of the overallinstallation pro

Seite 60

The Update returned an error message appearsWhen installing any component, if the installation fails, HP SUM displays the Update returnedan error mess

Seite 61 - 5 Troubleshooting

• The Symantec Endpoint Protection product blocks HP SUM ability to communicate with remotetargets if the Network Threat Analysis feature is enabled.

Seite 62

1. Click Start→Control Panel→Administrative Tools→Windows Firewall with AdvancedSecurity→Inbound Rules→Remote Administration (NP-IN).2. Select Enabled

Seite 63

10. Click OK to ensure new firewall rules have been implemented.11. Restart HP SUM.Performing these steps allows HP SUM to function, although after a

Seite 64 - Configuring firewall settings

inability to access system resources. For IPv6 networks, host discovery failures can be caused bythe incorrect configuration of the IPv6 network.Solut

Seite 65

• Use the DNS hostname instead of IPv6 address to ensure the address is correct.• Verify that you can connect to the admin$ share using the credential

Seite 66 - IPv6 network issues

The user-specified reboot message does not appear when using a Japanese characterset on a Linux operating systemSolution: None.You can specify a messa

Seite 67 - IPv6 network issues 67

NOTE: HP SUM does not support third-party controllers. This includes flashing hard drivesbehind these controllers.• Remote online deployment of IO Car

Seite 68 - Operation issues

hp-minx-en-1.4.3.1-1.src.rpm and on the Installation Results screen, it appears ashp-minx-en-kmp-default-1.4.3.1_2.6.27.19_5-1.x86_64.rpm.Solution: No

Seite 69 - Operation issues 69

6 Support and other resourcesInformation to collect before contacting HPBe sure to have the following information available before you contact HP:• Ac

Seite 70 - 70 Troubleshooting

Related informationDocuments• HP Smart Update Manager Release Notes• HP Service Pack for ProLiant Release Notes• HP Service Pack for ProLiant Server S

Seite 71 - 6 Support and other resources

Typographic conventionsTable 4 Document conventionsElementConventionCross-reference links and e-mail addressesBlue text: Table 4 (page 73)Website addr

Seite 72 - Related information

additional features. For more information on the Insight Remote Support Advanced software,see the HP website at http://www.hp.com/go/insightremotesupp

Seite 73 - Typographic conventions

7 Documentation feedbackHP is committed to providing documentation that meets your needs. To help us improve thedocumentation, send any errors, sugges

Seite 74

Acronyms and abbreviationsAMS Agentless Management ServiceCPLD complex programmable logic deviceDNS domain name systemFPGA Field Programmable Gate Arr

Seite 75 - 7 Documentation feedback

IndexAadvanced topics, 57arguments, 33Bbaselinecreating, 18blocked HP SUM, recovering from, 64bundle filter optionsAdd Repository, 16Edit Repository,

Seite 76 - Acronyms and abbreviations

installation options, 27introduction, 6IPv6 network configurationsConfiguring IPv6 for Windows Server 2008, 58Configuring IPv6 networks with HP SUM, 5

Seite 77

Vversion discrepancy issue, 69virtual media access, 68VMwareupdates, 22Wwebsitesproduct manuals, 72Windows smart components, return codes, 4279

Seite 78 - 78 Index

HP deliverableHP SUM commandDescriptionScenarioUse this scenario when you:Interactive, graphicaldeployment on a local host• Online:◦ HP Service Pack f

Seite 79

HP deliverableHP SUM commandDescriptionScenarioUser1 -passwordPW1• Need to update allenclosure firmware• Need to target VMwarehost serversThe HP SPP t