Switch Stacking
CLI Command Reference
September 2014 Page 31
HP Moonshot Switch Module CLI Command Reference
Example: The following shows example CLI display output for the command.
(Routing) #show switch
(Routing) #show switch
Management Standby Preconfig Plugged-in Switch Code
SW Switch Status Model ID Model ID Status Version
--- ---------- --------- ---------------- ---------------- ------------- -----------
1 Mgmt Sw Moonshot-180G Moonshot-180G OK H.9.1.2
2 Stack Mbr Oper Stby Moonshot-180G Moonshot-180G OK H.9.1.2
When you specify a value for unit, the following information appears.
Plugged-In Model
Identifier
The model identifier of the switch in the stack. Model Identifier is a 32-character field
assigned by the device manufacturer to identify the device.
Switch Status The switch status. Possible values for this state are: OK, Code Mismatch, or Not Present. A
mismatch indicates that a stack unit is running a different version of the code than the
management unit.
If there is a Stacking Firmware Synchronization operation in progress status is shown as
Updating Code.
Code Version The detected version of code on this switch.
Term Definition
Switch Switch ID
Management Status Indicates whether the switch is the Primary Management Unit, a stack member, or
the status is unassigned.
Hardware Management
Preference
The hardware management preference of the switch. The hardware management
preference can be disabled or unassigned.
Admin Management
Preference
The administrative management preference value assigned to the switch. This
preference value indicates how likely the switch is to be chosen as the Primary
Management Unit.
Switch Type The 32-bit numeric switch type.
Preconfigured Model
Identifier
The model identifier for this switch that has been preconfigured for the unit prior
to joining the stack. Model Identifier is a 32-character field assigned by the device
manufacturer to identify the device.
Plugged-in Model
Identifier
The model identifier for this switch detected by the hardware. Model Identifier is a
32-character field assigned by the device manufacturer to identify the device.
Switch Status The switch status. Possible values are OK, Code Mismatch, or Not Present.
Switch Description The switch description.
Detected Code in Flash The version of code that is currently stored in FLASH memory on the switch. This
code executes after the switch is reset. If the switch is not present and the data is
from pre-configuration, then the code version is “None”.
SFS Last Attempt Status The stack firmware synchronization status in the last attempt for the specified unit.
Serial Number
(Moonshot-180G only)
The unique serial number assigned to the switch.
Up Time The system up time.
Term Definition