Link Rate (0=Auto, 1=1Gb, 2=2Gb, 4=4Gb, 8=8GB) [Auto ]
Frame Size (0=512B, 1=1024B, 2=2048B) [2048 ]
Execution Throttle (Min=16, Max=65535) [256 ]
All attribute values for Port 2 that have been changed will now be saved.
Example 2:
MEZ75 (admin) #> set fc
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
WARNING:
The following command might cause a loss of connections to both ports.
Configuring FC Port: 1
-------------------------
Port Status (0=Enable, 1=Disable) [Enabled ]
Link Rate (0=Auto, 1=1Gb, 2=2Gb, 4=4Gb, 8=8GB) [Auto ]
Frame Size (0=512B, 1=1024B, 2=2048B) [2048 ]
Execution Throttle (Min=16, Max=65535) [256 ]
All attribute values for Port 1 that have been changed will now be saved.
Configuring FC Port: 2
-------------------------
Port Status (0=Enable, 1=Disable) [Enabled ]
Link Rate (0=Auto, 1=1Gb, 2=2Gb, 4=4Gb, 8=8GB) [Auto ]
Frame Size (0=512B, 1=1024B, 2=2048B) [2048 ]
Execution Throttle (Min=16, Max=65535) [256 ]
All attribute values for Port 2 that have been changed will now be saved.
Configuring FC Port: 3
-------------------------
Port Status (0=Enable, 1=Disable) [Enabled ]
Frame Size (0=512B, 1=1024B, 2=2048B) [2048 ]
Execution Throttle (Min=16, Max=65535) [256 ]
All attribute values for Port 3 that have been changed will now be saved.
Configuring FC Port: 4
-------------------------
Port Status (0=Enable, 1=Disable) [Enabled ]
Frame Size (0=512B, 1=1024B, 2=2048B) [2048 ]
Execution Throttle (Min=16, Max=65535) [256 ]
All attribute values for Port 4 that have been changed will now be saved.
Set features
Applies license keys to the module. The date and time must be set on the module prior to applying
a new feature key. (This option is not currently supported. It will be supported in a future release.)
Admin sessionAuthority
set featuresSyntax
Example:
MEZ75 (admin) #> set features
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
234 Command reference