Select the step between histogram columns of the report. By default each column's IO density is 4
times the previous column, but a step of 2 or 8 can also be specified.
-cpg
Treat the specifier as a CPG name instead of an AO configuration name.
SPECIFIERS
<aocfg_name>
The name of the AO configuration to generate the report for.
<cpg_name>
The name of the CPG to generate the report for (if the -cpg option is specified).
EXAMPLES
The following example shows region IO performance density report for a CPG beginning 2 hours
(7200 seconds) ago:
cli% srrgiodensity -btsecs -7200 -cpg cpg_name
srrgiodensity 557