HP 3PAR Betriebsanweisung Seite 664

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 676
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 663
upgradepd
DESCRIPTION
The upgradepd command upgrades the Physical Disk (PD) firmware.
SYNTAX
upgradepd [-f] [-skiptest] {-a | -w <WWN>... | <PD_ID>...}
AUTHORITY
Super, Service
Any role granted the pd_upgrade right
NOTE: You need access to all domains in order to run this command.
OPTIONS
f
Upgrades the PD firmware without requiring confirmation.
skiptest
Skips the 10 second diagnostic test normally completed after each PD upgrade.
a
Specifies that all PDs with valid IDs and whose firmware is not current are upgraded. If this option
is not specified, then either the w option or PD_ID specifier must be issued on the command line.
w <WWN>...
Specifies that the firmware of either one or more PDs, identified by their WWNs, is upgraded. If
this option is not specified, then either the a option or PD_ID specifier must be issued on the
command line.
SPECIFIERS
<PD_ID>...
Specifies that the firmware of either one or more PDs identified by their IDs (PD_ID) is upgraded.
If this specifier is not used, then the a option or w option must be issued on the command line.
RESTRICTIONS
Access to all domains is required to run this command.
EXAMPLES
The following example displays the upgrade of all PDs:
cli% upgradepd a
NOTES
PDs can be upgraded while I/O is occurring.
If a disk with RAID-0 chunklets is upgraded, I/O to those chunklets at the time of the upgrade
results in data loss. This is not applicable to other RAID types.
Specify the w option when upgrading unadmitted PDs.
664 Upgrade Commands
Seitenansicht 663
1 2 ... 659 660 661 662 663 664 665 666 667 668 669 ... 675 676

Kommentare zu diesen Handbüchern

Keine Kommentare