The Status page also shows:
Devices being tested
Tests currently running
Overall test time
Individual test times
Condition status of each test
Log tab
The Log tab consists of the following views.
Test LogDisplays all tests that have been executed, the number of times a test was executed, the
number of times a test failed, and the time it took to complete the test.
The Clear Test Log button clears the contents of the Test Log.
Error Log—Displays the tests that have failed during diagnostic testing. In addition to displaying the
device and test, this section might also include error details. The description section describes the error
that the diagnostic test found. The Recommended Repair section gives a recommended action you
should perform to resolve the hardware problem. The error count is the number of times the test has
failed. The Clear Error Log button clears the contents of the Error Log.
Help tab
The Help tab provides these views:
HP Insight Diagnostics—Provides introductory and detailed information about Insight Field
Diagnostics.
Error Codes—Provides error code listings, including devices tested, messages, and
recommended repair information.
Test Components—Reloads and refreshes all components and displays component details after
the refresh.
POST error messages
Power On Self Test (POST) is a program run at startup that initializes and runs tests on installed
hardware. An audible and/or visual message appears if the POST encounters a problem. POST checks
the following items to ensure that the workstation system is functioning properly:
NOTE: If the power-on password is set, a key icon appears on the screen while POST is running. You
must enter the password before continuing.
Table 5-18 POST error messages
Screen message Probable cause Recommended action
101—Option ROM Error System ROM checksum. Verify the correct ROM:
1. Flash the ROM, if needed.
2. If an expansion card was recently added, remove
it to find out if the problem remains.
138 Chapter 5 System diagnostics and troubleshooting ENWW