50 APPENDIX A: CABLE SPECIFICATIONS
Serial Interface Cable Synchronous and Asynchronous Mode
V.35 and V.24 (EIA/TIA-232) standards support synchronous operating mode. V.24
(EIA/TIA-232) also supports the asynchronous operating mode. The maximum
transmission distance and baud rate of the signal vary with the operating mode.
Tab le 20 Transmission Rate and Transmission Distance of V.24 (EIA/TIA-232)/V.35 Cable
V.24 (EIA/TIA-232) V.35
Baud rate (bps)
Maximum
transmission
distance (m)
Baud rate (bps)
Maximum
transmission
distance (m)
2400 60 2400 1250
4800 60 4800 625
9600 30 9600 312
19200 30 19200 156
38400 20 38400 78
64000 20 54000 60
115200 10 64000 50
- - 2048000 30
The baud rate should not exceed 64 Kbps when the V.24 cable operates in
synchronous mode.
DTE and DCE Mode
The synchronous serial interface can operate in both DTE and DCE modes. For two
devices connected directly, one device should operate in DTE mode, and the other
device should operate in DCE mode. The DCE device provides a synchronous clock
and specifies the transmission rate, the DTE device accepts the synchronous clock
and communicates at the specified transmission rate. Usually, the router serves as
the DTE device. To determine whether the device is a DTE or a DCE, refer to the
user manual for the device.
Tab le 21 Typical DTE and DCE
Type of Equipment Type of Interface Typical Equipment
DTE male PC or router
DCE female Modem, multiplexer or
CSU/DSU
The asynchronous serial interface generally is connected to a modem or a terminal
adapter (TA) to act as the dial-up interface. You do not need to determine if the
device is DTE or DCE, you must only select the appropriate baud rate.
The synchronous/asynchronous serial port cable is connected to a DB-50
receptacle. Proper connection cable needs to be selected for the protocol applied.
Four types of synchronous/asynchronous serial port cables are available. However,
these cables are optional and you must select the proper one based on your
requirements when you purchase the router All these types of cables have a DB-50