HP 5000 Router Series Installationshandbuch Seite 51

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 62
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 50
Ethernet Cable 49
Table 18 Straight-through Network Cable Pinouts
RJ-45 Signal
Category 5
twisted pair
Signal Direction RJ-45
1 TX+ White (Orange) —> 1
2 TX- Orange —> 2
3 RX+ White (Green) <— 3
4 - Blue - 4
5 - White (Blue) - 5
6 RX- Green <— 6
7 - White (Brown) - 7
8 - Brown - 8
Table 19 Crossover Network Cable Pinouts
RJ-45 Signal
Category 5
Twisted Pair
Signal Direction RJ-45
1 TX+ White (Orange) —> 3
2 TX- Orange —> 6
3 RX+ White (Green) <— 1
4 - Blue - 4
5 - White (Blue) - 5
6 RX- Green <— 2
7 - White (Brown) - 7
8 - Brown - 8
You can use the table as a reference while distinguishing or preparing the two
kinds of Ethernet cables. While preparing the Ethernet cables, follow the
chromatogram given in this table to arrange the wires. Otherwise, communication
quality will be affected even though the equipment at two ends is connected.