System LEDs and switches
HP ProLiant DL585 Server User Guide E-11
Table E-9: BBWCE LED descriptions continued
Server status LED color LED status Battery module status
Server is on and is in the
first 30 seconds after
power-up
Amber (1) or
green (2)
On Temporary lock-out state; data
was lost due to cable being
detached
Server is off and is in data
retention mode
Amber (1) Blinking every
15 seconds
User data held in write cache is
being backed up
CAUTION: After the server is powered down, wait 15 seconds and then check the
illumination pattern of the LEDs before unplugging the cable from the battery module.
If the amber LED blinks after 15 seconds, do not remove the cable
from the battery module. This module is backing up data, and data will be lost if
the cable is detached.
If neither LED blinks after 15 seconds, it is safe to remove the
cable from the battery module.