Seitenansicht 61
58
Monitor Alert List
NOTE For Windows NT, the monitor capability is integrated into the HP NetRAID
Assistant utility.
NetWare Monitor Messages
Condition Messages
Physical drive state changes HP NetRAID-Adapter # (Channel: SCSI ID#) state (previous
state) to (new state)
Logical drive state change HP NetRAID-Adapter # LD-# state (previous state) to (new
state)
Physical drive rebuilding at
startup of monitor
Warning: HP NetRAID-Adapter # Channel: SCSI ID# at
startup is in REBUILD state
Logical drive state at
startup
HP NetRAID-# LD-# state at startup is X
The number of adapters
found by monitor
HP NetRAID Mon: # HP NetRAID Adapters Found
NetWare Monitor Messages
OS/2 Monitor Messages
Condition Messages
Logical drive state change Adp = # LogDrv # state changed from (previous state) to
(new state).
Physical drive state change Adp = # PhysDrv at Ch # Tid # state changed from
(previous state) to (new state).
Monitor started HP NetRAID Monitor for OS/2
Memory allocation failure Malloc Failure
Adapter not identified No HP NetRAID Adapters Found
Adapter rebuild completed
X%
Adp = # Rebuilding Ch# Tid # Percent Rbld = X
OS/2 Monitor Messages
Seitenansicht 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 83 84

Kommentare zu diesen Handbüchern

Keine Kommentare