Hp 2000SA G2-Modular-Smart-Array Bedienungsanleitung Seite 1

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Lager Hp 2000SA G2-Modular-Smart-Array herunter. HP 2000SA G2-Modular-Smart-Array User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
HP 2000sa G2 Modular Smart Array
User Guide
Part number: 488320-005
First edition: January 2013
Seitenansicht 0
1 2 3 4 5 6 ... 75 76

Inhaltsverzeichnis

Seite 1 - User Guide

HP 2000sa G2 Modular Smart ArrayUser GuidePart number: 488320-005First edition: January 2013

Seite 3 - Contents

HP 2000sa G2 Modular Smart Array User Guide 11About this guideThis guide provides information about the HP StorageWorks 2312sa G2 Modular Smart Array

Seite 4

12Document conventions and symbolsWARNING! Indicates that failure to follow directions could result in bodily harm or death.CAUTION: Indicates that fa

Seite 5

HP 2000sa G2 Modular Smart Array User Guide 13Rack stabilityWARNING! To reduce the risk of personal injury or damage to equipment:• Extend leveling ja

Seite 6

14• http://www.hp.com/go/msa• http://www.hp.com/service_locator • http://www.hp.com/go/storage • http://www.hp.com/support/ • http://www.docs.hp.com D

Seite 7

HP 2000sa G2 Modular Smart Array User Guide 151OverviewThe 2312sa G2 Modular Smart Array and 2324sa G2 Modular Smart Array are high-performance storag

Seite 8

16 Overview

Seite 9

HP 2000sa G2 Modular Smart Array User Guide 172ComponentsFront panel components2312sa G22324sa G21 Enclosure ID LED2 Disk drive Online/Activity LED3 D

Seite 10

18 ComponentsDisk drive bay numbers2312sa G22324sa G2Rear panel components 2312sa G2 and 2324sa G2MSA2000123456789101112MSA20001 2 3 4 5 6 7 8 9 10111

Seite 11 - About this guide

HP 2000sa G2 Modular Smart Array User Guide 19MSA2000 3.5" 12-drive enclosureMSA70 2.5” 25-drive enclosureThe 2324sa G2 can also be attached to a

Seite 12 - Monospace, italic font

Legal and notice information© Copyright 2009, 2013 Hewlett-Packard Development Company, L.P.The information combined herein is subject to change witho

Seite 13

20 ComponentsCAUTION: To preserve the existing data stored in the CompactFlash, you must transport the CompactfFlash from the failed controller to the

Seite 14 - Documentation feedback

HP 2000sa G2 Modular Smart Array User Guide 213Installing the enclosuresInstallation checklistThe following table outlines the steps required to insta

Seite 15 - 1Overview

22 Installing the enclosuresConnecting controller and drive enclosuresConnecting controller and MSA2000 3.5" 12-drive enclosuresYou can connect u

Seite 16 - 16 Overview

HP 2000sa G2 Modular Smart Array User Guide 23Table 3 SAS cable requirementsMini-SAS to SAS cables must be purchased separately.0.5m cables are recomm

Seite 17 - 2Components

24 Installing the enclosuresFigure 3 Cabling connections between a dual-controller enclosure and three MSA2000 3.5" 12-drive enclosuresFigure 4 C

Seite 18 - 12 34567 1

HP 2000sa G2 Modular Smart Array User Guide 25Figure 5 Cabling connections between a dual-controller enclosure and three MSA70 drive enclosures0B0ACon

Seite 19 - MSA70 2.5” 25-drive enclosure

26 Installing the enclosuresFigure 6 Cabling connections between a dual-controller enclosure and mixed drive enclosures.TIP: For comprehensive configu

Seite 20 - Super-capacitor pack

HP 2000sa G2 Modular Smart Array User Guide 27Obtaining IP valuesNOTE: For help with configuring your MSA2000 G2 product, also see the MSA2000 Softwar

Seite 21 - 3Installing the enclosures

28 Installing the enclosures2. Use the provided micro-DB9 serial cable to connect controller A to a serial port on a host computer.Your package conten

Seite 22 - 22 Installing the enclosures

HP 2000sa G2 Modular Smart Array User Guide 29# set network-parameters ip 192.168.0.11 netmask 255.255.255.0 gateway 193.168.0.10 controller b7. Type

Seite 23

HP 2000sa G2 Modular Smart Array User Guide 3About this guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 24

30 Installing the enclosures

Seite 25

HP 2000sa G2 Modular Smart Array User Guide 314 Connecting hostsHost system requirementsData hosts connected to 2312sa G2 and 2324sa G2 arrays must me

Seite 26 - Testing enclosure connections

32 Connecting hostsThe 2312sa Modular Smart Array and 2324sa Modular Smart Array use Unified LUN Presentation (ULP) — a controller firmware feature en

Seite 27 - Obtaining IP values

HP 2000sa G2 Modular Smart Array User Guide 33Connecting switch attach configurationsIMPORTANT:• Any number or combination of LUNs can be shared among

Seite 28 - SAS 1 SAS 2

34 Connecting hostsBlade enclosure configurationBlade servers/two 3Gb SAS BL switchesConnecting remote management hostsThe management host directly ma

Seite 29 - IP-address

HP 2000sa G2 Modular Smart Array User Guide 355 Basic operationPowering on/powering offBefore powering on the enclosure for the first time:• Install a

Seite 30 - 30 Installing the enclosures

36 Basic operationFor software and firmware updates, go to http://www.hp.com/go/msa. Select MSA SAN Arrays, select your product, and go to Support.For

Seite 31 - 4 Connecting hosts

HP 2000sa G2 Modular Smart Array User Guide 376 LED descriptionsFront panel LEDsLED Description Definition1 Enclosure ID Green — OnEnables you to corr

Seite 32 - One server/one HBA/dual path

38 LED descriptionsDisk drive LEDsLED Description1 Fault/UID (amber/blue)2Online/Activity (green)Table 6 Disk drive LED combinations Online/Activity (

Seite 33

HP 2000sa G2 Modular Smart Array User Guide 39Blinking regularly (1 Hz) OffCAUTION: Do not remove the drive. Removing a drive may terminate the curren

Seite 34 - Blade enclosure configuration

4Blade enclosure configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Blade servers/two

Seite 35 - 5 Basic operation

40 LED descriptionsRear panel LEDs2312sa G2 and 2324sa G2LED Description Definition1 Power supply LEDs See Power supply LEDs on page 43.2 Host 3Gb SAS

Seite 36 - 36 Basic operation

HP 2000sa G2 Modular Smart Array User Guide 41NOTE: Once a Link Status LED is lit, it remains so, even if the controller is shutdown via SMU or CLI.Wh

Seite 37 - 6 LED descriptions

42 LED descriptionsMSA2000 3.5" 12-drive enclosureMSA70 2.5” 25-drive enclosureThe 2324sa G2 can also be attached to an MSA70 running firmware ve

Seite 38 - Disk drive LEDs

HP 2000sa G2 Modular Smart Array User Guide 43Power supply LEDsPower redundancy is achieved through two independent load-sharing power supplies. In th

Seite 39 - Online/Activity

44 LED descriptions

Seite 40 - Rear panel LEDs

HP 2000sa G2 Modular Smart Array User Guide 457 Configuring a system for the first timeConfiguring your web browser for SMUBefore using SMU to perform

Seite 41

46 Configuring a system for the first time• The System Status panel shows how many events of each severity have occurred in the system. To view event

Seite 42

HP 2000sa G2 Modular Smart Array User Guide 47To obtain the date and time from an NTP server1. In the Configuration View panel, right-click the system

Seite 43 - Power supply LEDs

48 Configuring a system for the first timeUsing the Configuration WizardThe Configuration Wizard helps you initially configure the system or change sy

Seite 44 - 44 LED descriptions

HP 2000sa G2 Modular Smart Array User Guide 49Using the Provisioning WizardThe Provisioning Wizard helps you create a vdisk with volumes, and to map t

Seite 45 - Signing in to SMU

HP 2000sa G2 Modular Smart Array User Guide 5Temperature sensors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Seite 46

50 Configuring a system for the first time

Seite 47

HP 2000sa G2 Modular Smart Array User Guide 518TroubleshootingFault isolation methodologyThe 2000sa G2 Modular Smart Array storage system provides man

Seite 48

52 TroubleshootingCorrecting enclosure IDs When installing a system with drive enclosures attached, the enclosure IDs might not agree with the physica

Seite 49 - Signing out of SMU

HP 2000sa G2 Modular Smart Array User Guide 53Are both drive module LEDs off (Online/Activity and Fault/UID)?Is the drive module Fault/UID LED blinkin

Seite 50

54 TroubleshootingIs a connected port’s Expansion Port Status LED off?Is a connected port’s Network port link status LED off?Is the power supply’s AC

Seite 51 - 8Troubleshooting

HP 2000sa G2 Modular Smart Array User Guide 55Is the drive enclosure Fault/Service Required LED amber?Answer Possible Reasons ActionsNo System functi

Seite 52 - Diagnostic steps

56 TroubleshootingController failure in a single-controller configurationCache memory is flushed to CompactFlash in the case of a controller failure o

Seite 53

HP 2000sa G2 Modular Smart Array User Guide 57Isolating a host-side connection fault During normal operation, when a controller module host port is co

Seite 54 - 54 Troubleshooting

58 TroubleshootingIsolating a controller module expansion port connection fault During normal operation, when a controller module’s expansion port is

Seite 55

HP 2000sa G2 Modular Smart Array User Guide 59Sensor locationsThe storage system monitors conditions at different points within each enclosure to aler

Seite 57

60 TroubleshootingWhen a power supply sensor goes out of range, the Fault/ID LED illuminates amber and an event is logged to the event log.Power suppl

Seite 58 - 58 Troubleshooting

HP 2000sa G2 Modular Smart Array User Guide 61A Environmental requirements and specificationsSafety requirementsInstall the system in accordance with

Seite 59 - Temperature sensors

62 Environmental requirements and specificationsWeight and placement guidelinesRefer to Physical requirements on page 63 for detailed size and weight

Seite 60

HP 2000sa G2 Modular Smart Array User Guide 63NOTE: Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods

Seite 61 - Safety requirements

64 Environmental requirements and specificationsElectrical requirementsSite wiring and power requirementsEach enclosure has two power and cooling modu

Seite 62 - Management host requirements

HP 2000sa G2 Modular Smart Array User Guide 65B Electrostatic dischargePreventing electrostatic dischargeTo prevent damaging the system, be aware of t

Seite 63 - Environmental requirements

66 Electrostatic discharge

Seite 64 - Electrical requirements

HP 2000sa G2 Modular Smart Array User Guide 67C Regulatory compliance and safetyRegulatory complianceFederal Communications Commission noticePart 15 o

Seite 65 - B Electrostatic discharge

68 Regulatory compliance and safety• 1-281-514-3333To identify this product, refer to the part, Regulatory Model Number, or product number found on th

Seite 66 - 66 Electrostatic discharge

HP 2000sa G2 Modular Smart Array User Guide 69Laser product labelThe optional label in Figure 6-1 or equivalent may be located on the surface of the H

Seite 67 - Regulatory compliance

HP 2000sa G2 Modular Smart Array User Guide 7Figures1 Cabling connections between a single-controller enclosure and one MSA2000 3.5" 12-drive en

Seite 68

70 Regulatory compliance and safetyBSMI noticeJapanese noticeKorean noticesSafetyBattery replacement noticeYour computer is equipped with a lithium ma

Seite 69 - European Union notice

HP 2000sa G2 Modular Smart Array User Guide 71WARNING! Your computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkal

Seite 70 - Battery replacement notice

72 Regulatory compliance and safety• Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.• Place part

Seite 71 - Electrostatic discharge

HP 2000sa G2 Modular Smart Array User Guide 73IndexAaccessingthe CLI 27accessing the SMU 45accumulators 71audience 11Avis Canadien, regulatory complia

Seite 72 - Grounding methods

74Ffaultsisolatinga host-side connection 57expansion port connection fault 58methodology 51FCC (Federal Communications Commission)Class A Equipment, c

Seite 73

HP 2000sa G2 Modular Smart Array User Guide 75power cordcompliance notice 71current rating 71replacement 71set 71voltage rating 71power cord requireme

Seite 74

76web sitesHP documentation 11HP storage 14HP Subscriber’s choice 13web-browser configuration 45work mat, static-dissipating 72wrist strapsspecificati

Seite 76

HP 2000sa G2 Modular Smart Array User Guide 9Tables1 Document conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Kommentare zu diesen Handbüchern