Hp 2000SA G2-Modular-Smart-Array Bedienungsanleitung Seite 55

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 76
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 54
HP 2000sa G2 Modular Smart Array User Guide 55
Is the drive enclosure Fault/Service Required LED amber?
Answer Possible Reasons Actions
No System functioning properly. No action required.
Yes
(blinking)
One of the following errors
occurred:
Hardware-controlled
power-up error
Cache flush error
Cache self-refresh error
Check the event log for specific information regarding
the fault.
Isolate the fault.
Contact an authorized service provider for assistance.
Replace if necessary.
Yes A fault occurred.
If installing an I/O module
FRU, the module has not gone
online and likely failed its
self-test.
Check the event log for specific information regarding
the fault.
Isolate the fault.
Contact an authorized service provider for assistance.
Replace if necessary.
If installing an I/O module FRU, try removing and
reinstalling the new I/O module, and check the event
log for errors.
Seitenansicht 54
1 2 ... 50 51 52 53 54 55 56 57 58 59 60 ... 75 76

Kommentare zu diesen Handbüchern

Keine Kommentare