Power supply LEDs
Power redundancy is achieved through two independent load-sharing power supplies. In the event of a
power supply failure, or the failure of the power source, the storage system can operate continuously on a
single power supply. Greater redundancy can be achieved by connecting the power supplies to separate
circuits.
AC model DC model
LED Description Definition
1 Input Source Power good Green Power is on and input voltage is normal.
Off — Power is off or input voltage is below the minimum
threshold.
2 DC Voltage/Fan Fault/Service Required Amber — DC output voltage is out of range or a fan is
operating below the minimum required RPM.
Off — DC output voltage is normal.