Troubleshooting
166 HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
8003 Drive load did not complete
(The drive failed to successfully load a
tape.)
■ Press the Enter button to reboot.
■ Ensure the drive shows good status
through the drive status window.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Check the tape cartridge used in the last
operation for damage.
8004 Invalid drive was installed
(One or more installed drives are of a type
either unknown or not supported in the
current library personality.)
■ Press the Enter button to clear the
message.
■ Update the firmware if a newer revision
exists.
■ Invalid user initiated operation. Set
parameters correctly and try again.
9001 Orphan cartridge recovery
failed
(The master module could not successfully
return an orphan cartridge to a slot
location.)
■ Make sure there is one empty slot in a
magazine in the master module.
■ Press the Enter button to reboot.
■ Cycle power to the library or reboot using
the GUI touch screen.
■ Check pass-through alignment.
■ Ensure that there are no obstructions
inside the library (all cartridges are in
magazines).
■ Check the tape cartridge used in the last
operation for damage.
9003 Master pass-thru opto failed.
(The master module opto sensor was not
detected during the power-up Pass-Through
module inventory.)
■ Press the Enter button to reboot.
■ Run the sensor test, checking appropriate
sensor.
■ Determine if the pass-through may have
been plugged or unplugged while power
was on to the library.
■ Reinitialize or power-cycle the master it is
connected to. Ensure the pass-through is
functioning by observing whether or not
the pass-through car moves to either end
of the pass-through smoothly.
A001 SMX send error
(An attempt to place a message on a task’s
exchange generated a kernel error.)
■ Press the Enter button to reboot.
■ Cycle power to the library or reboot using
the GUI touch screen.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP