Troubleshooting
141HP StorageWorks MSL5000 and MSL6000 Series Tape Libraries User Guide
1001 SCSI Firmware Error
(Internal SCSI task processing error.
Unexpected state or hardware status.)
■ Turn off power to the library and inspect
connectors and cables.
■ Check the SCSI cable connections to make
sure they are secured.
■ Make sure the library controller board has
SCSI termination.
1002 SCSI FIFO Empty
(The SCSI controller data FIFO is empty but
should contain more data bytes.)
■ Turn off power to the library and inspect
connectors and cables.
■ Check the SCSI cable connections to make
sure they are secured.
■ Make sure the library controller board has
SCSI termination.
1003 SCSI FIFO Error
(The SCSI controller data FIFO should be
empty but still contains data bytes.)
■ Turn off power to the library and inspect
connectors and cables.
■ Check the SCSI cable connections to make
sure they are secured.
■ Make sure the library controller board has
SCSI termination.
1004 SCSI Gross Error
(The SCSI controller detected a gross error
condition. Invalid SCSI bus phase or DMA
error.)
■ Turn off power to the library and inspect
connectors and cables.
■ Ensure SCSI options are set correctly.
■ Check the SCSI cable connections to make
sure they are secured.
■ Make sure the library controller board has
SCSI termination.
■ Check host SCSI cable and connections.
1005 Illegal SCSI Cnt Cmd
(Either an invalid command was sent to the
SCSI controller, or the controller was not in
the correct mode.)
■ Turn off power to the library and inspect
connectors and cables.
■ Check that application is certified to work
with your library and has up-to-date
patches.
■ Ensure SCSI options are set correctly.
■ Check the SCSI cable connections to make
sure they are secured.
■ Make sure the library controller board has
SCSI termination.
■ Check host SCSI cable and connections.
Table 11: Fault Symptom Codes (Continued)
FSC Message ERP