Seitenansicht 6
Installation
311053C 7
Mount Gun
Reciprocating Arm Rod Mount
Manifolds 241161 and 241162
To mount the gun on a reciprocating arm rod [0.5 in. (13
mm) diameter maximum]:
1. Insert the mounting bar (A) through the hole in the
manifold as shown in F
IG. 3.
2. Secure the gun to the bar by tightening the mount-
ing screw (B).
3. Ensure the tip of the gun is 8 to 10 in. (150 to 200
mm) from the surface of the object being sprayed.
Stationary Support Mount
All Manifolds
To mount the gun on a stationary support (refer to F
IG.
4. and Mounting Hole Layout, page 28):
1. Attach the gun to the support with two M5 x 0.8 cap-
screws (C). The screws must be long enough to
engage the threaded holes in the gun manifold to a
depth of 1/4 in. (6 mm).
2. Ensure the tip of the gun is 8 to 10 in. (150 to 200
mm) from the surface of the object being sprayed.
Use the 1/8 in. alignment pin (P) to assist in
orienting the gun.
F
IG. 3: Reciprocating Arm Mount
TI8111a
A
B
P
F
IG. 4: Stationary Support Mount
C
TI8112a