Hp XP RAID Manager Software Bedienungsanleitung Seite 33

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 129
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 32
The following table shows the relationship between Cnt Ac-S/Cnt Ac-J pair operations and SS
status.
SS statusCnt Ac-S / Cnt Ac-J operations
PSUERCPYCOPY
2
PSUS, PFUSPAIR,
PFUL
COPY
1
NoNoNoNoNoNoCreate pair 3
YesN/AYesYesYesYesSplit pair
YesN/AYesYesYesYesResync pair
YesN/AYesYesYesYesDelete pair
YesN/AYesYesYesYesSwitch operations to the remote
site
1. “COPY” is the status during the initial copy.
2. “COPY” is the status during a resynchronization.
3. To use a Cnt Ac-S or Cnt Ac-J S-VOL as the SS P-VOL, you must first create the Cnt Ac-S or Cnt Ac-J pair then create
the SS pair.
To view a list of the corresponding RAID Manager pair status names, see “Remote Web Console
and RAID Manager pair status names” (page 67).
Cnt Ac-S and Cnt Ac-J volume backup in 3DC multi-target configuration
You can use SS to back up Cnt Ac-S and Cnt Ac-J volumes on the remote sites in a 3DC multi-target
configuration.
The following figure shows how to back up the volumes.
Pair 1 is the Cnt Ac-S pair. Pair 2 is the Cnt Ac-J pair. Pair 3 is the Cnt Ac-J pair for a delta
resynchronization. Pair 4, pair 5, and pair 6 are the SS pairs.
To back up the volumes, complete the following:
1. Create the 3DC multi-target and delta resynchronize pairs (pairs 1, 2, and 3).
2. Create pair 4.
3. Create pairs 5 and 6.
NOTE: You cannot share SS volumes in 3DC Cnt Ac-J/Cnt Ac-J configurations.
Auto LUN V2
To share the source Auto LUN V2 pair with an SS P-VOL, complete the following:
Auto LUN V2 33