Hp Surestore Disk Array 12h and FC60 Bedienungsanleitung Seite 30

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 466
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 29
30 Disk Enclosure Components
Each BCC provides two LVD SCSI ports (B in Figure 5) for connection to the controller
enclosure.
The EEPROM on each BCC stores 2
K
bytes of configuration information and user-defined
data, including the manufacturer serial number, World Wide Name, and product number.
The following are additional features of the BCC:
LEDs (C in Figure 5) show the status of the BCC and the bus.
A rotary switch (D) used to set the enclosure (tray) ID which is used by internal
controller operations, and also by the management tools to identify each enclosure.
DIP switches set disk enclosure options. The only option used by the Disk Array FC60
is the full-bus/split-bus mode.
Screws (F) prevent the card from being unintentionally disconnected.
Cam levers (G) assist in installing and removing the BCC from the enclosure, ensuring
a tight connection with the backplane.
BCC functions include drive addressing, fault detection, and environmental services.
Seitenansicht 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 465 466

Kommentare zu diesen Handbüchern

Keine Kommentare