Hp StorageWorks XP10000 Disk Array Bedienungsanleitung Seite 193

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 220
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 192
NOTE:
If a VDEV number starts with E (for example, E1-1-(1)), the VDEV belongs to a parity group that
consists of one or more external LUs.
NOTE:
If a VDEV number starts with V (for example, V1-1-(1)), the VDEV belongs to a parity group that
consists of one or more virtual volumes (V-VOLs).
Emulation: Emulation type of the CVS volume to be created (OPEN-V).
Capacity:CVS
volume's capacity displayed in the unit selected from the Capacity Unit list in
the Make Volume pane (1).
CU:LDEV: CU:LDEV number of the CVS volume to be created.
NOTE:
If an LDEV number ends with # (for example, 00:01#), the LDEV is an external LU. For more
information
about external LUs, see the
HP StorageWorks External Storage XP user guide
.
NOTE:
If an LDEV number ends with V (for example, 00:00V), the LDEV is a virtual volume (V-VOL). For
more information about virtual volumes, see the
HP StorageWorks Snapshot XP user guide
.
Back: Returns to the Make Volume pane (2) or Make Volume pane (3).
OK: Registers the Make Volume settings, and returns to the Customized Volume pane.
Cancel: Cancels the Make Volume settings, and returns to the Customized Volume pane.
Volume Initialize pane (1)
Use this pane to initialize CVS volumes other than OPEN-V.
Figure 102 Volume Initialize pane (1)
This pane has the following features:
HP StorageWorks LUN Conguration and Security Manager XP user guide for the
XP12000/XP10000/SVS200
193
Seitenansicht 192
1 2 ... 188 189 190 191 192 193 194 195 196 197 198 ... 219 220

Kommentare zu diesen Handbüchern

Keine Kommentare