Hp StorageWorks 2.32 Edge Switch Bedienungsanleitung Seite 88

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 202
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 87
Configuring the switch88
Configuring ports procedure
To configure ports, use the following steps:
1. Select Configure > Ports. The Configure Ports dialog box appears.
Figure 27 Configure Ports dialog box (Edge Switch 2/32)
Ports are numbered from 0 through 24 for the Edge Switch 2/24 and 0 through 31 for the
Edge Switch 2/32.
2. Click a Name box and type a name that reflects the end device connected through the port.
For example, use XYZ Server, where XYZ is the brand name of the server.
3. Block or unblock operation for a port by clicking the check box in the Blocked column. When
a check mark displays, the port is blocked.
4. (Edge Switch 2/32 only.) Enable or disable extended distance buffering for the port by clicking
a check box in the 10-100 km column. When a check mark displays, extended distance
buffering is enabled.
5. If a switch supports BB Credit, the RX BB Credit column replaces the 10-100km column.
Use this to set minimum and maximum allowable port BB credit values as follows:
Seitenansicht 87