Figure 9 Disabling Multi-blade FC connections
Virtual Connect 3.10 features that must be disabled in a VC Domain to be part of
the VC Domain Group with Virtual Connect firmware 3.0x, 2.3x and 2.1x
NOTE: To disable any of the FC SAN or Flex-10 iSCSI features, the last connection in the feature
table must be deleted first.
Flex-10 iSCSI Connections are not supported. To disable this feature:
1. Log on to HP Virtual Connect Manager.
2. Expand Server Profiles in the navigation pane and select the server profile with Flex-10 iSCSI
connections.
3. Right-click on the last Flex-10 iSCSI connection and select Delete Connection as displayed in
the following figure:
Figure 10 Removing Flex-10 iSCSI Connections
4. Continue selecting the last Flex-10 iSCSI connection until all connections are removed.