Chapter 11 269
Managing SNAplus2 Clients
Managing Win32 Clients
The Registry data type of this value is REG_SZ.
To trace CPI-C API messages, set this parameter to
YES; otherwise, set it to NO.
This parameter is optional. If it is not specified, the
default is NO. If the all_api parameter is set to YES,
this parameter is ignored, and CPI-C messages are
traced.
csv
The Registry data type of this value is REG_SZ.
To trace CSV API messages, set this parameter to YES;
otherwise, set it to NO.
This parameter is optional. If it is not specified, the
default is NO. If the all_api parameter is set to YES,
this parameter is ignored, and CSV messages are
traced.
rui
The Registry data type of this value is REG_SZ.
To trace LUA RUI messages, set this parameter to YES;
otherwise, set it to NO.
This parameter is optional. If it is not specified, the
default is NO. If the all_api parameter is set to YES,
this parameter is ignored, and LUA RUI messages are
traced.
nof
The Registry data type of this value is REG_SZ.
To trace NOF API messages, set this parameter to YES;
otherwise, set it to NO. NOF messages are not used
directly by applications on Win32 clients, but are used
internally by SNAplus2 components in obtaining
configuration information.
This parameter is optional. If it is not specified, the
default is NO. If the all_api parameter is set to YES,
this parameter is ignored, and NOF messages are
traced.
ms
The Registry data type of this value is REG_SZ.
To trace MS API messages, set this parameter to YES;
otherwise, set it to NO.