2. Enter a desired interval in New Span (sec).
The specifiable range is between 0 and 3600 seconds, with a default of 0.
We recommend setting a value of 0.
To leave the monitoring interval as is, leave New Span (sec) blank,
type ! and press the Enter key. You will be returned to the Hitachi
Network Objectplaza Trace Library setup menu.
Note that when you specify a monitoring interval of 0, even if you specify
the maximum number of messages in 7: Max messages per span, the
amount of integrated trace information to be output will not be adjusted.
3. Press the Enter key.
The new setting is applied and the Hitachi Network Objectplaza Trace
Library setup menu appears again.
4. In the Hitachi Network Objectplaza Trace Library setup menu, type 7 and
press the Enter key.
A screen to set the maximum number of messages output to the
integrated trace file based on the monitoring interval specified in 6:
Lookout span will appear. The current value is displayed in Current
Max (sec).
5. Adjust the maximum number of messages output to the integrated trace
files in New Max (sec).
The specifiable range is between 0 messages and 500 messages, with a
default of 0. If you want to increase the number of messages which are
output to the integrated trace file as much as possible, we recommend
setting a value of 0.
When you specify a monitoring interval of 0 in 6: Lookout span, the
value set in New Max (sec) will be disregarded.
Also, when you specify a value of 0 for New Max (sec), even if you
specify the monitoring interval in 6: Lookout span, the maximum
number of messages output will not be adjusted.
To leave the maximum number of messages output as is, leave New Max
(sec) blank, enter ! and press the Enter key. You will be returned to the
Hitachi Network Objectplaza Trace Library setup menu.
6. Press the Enter key.
3-88
Creating an HDLM Environment
Hitachi Dynamic Link Manager User Guide for AIX
®